IPC Eagle CT110ECS Скачать руководство пользователя страница 6

 

ENGLISH 

6 

E -Battery  compartment  (in  the  detergent  tank):  danger  of  short  circuit  between  the 

battery poles and presence of hydrogen during charging. 

3.4. 

Accessories 

  Bristle brushes:  for washing delicate floors and polishing; 

  Polypropylene brushes: for normal floor washing; 

  Tynex brushes: for removing accumulated stubborn dirt on resistant floors; 

  Drive disks: enable the following disks to be used: 

  Yellow  disks:  for  washing  and  polishing  marble  and  similar 

surfaces; 

  Green disks: for washing resistant floors; 

  Black  disks:  for  thorough  washing  of  resistant  floors  with 

stubborn dirt. 

  MICRO SCRUB: microfibre cleaning system used for normal floor washing; 

  CHEM DOSE (fig. 15): system for controlling detergent independently from the 

detergent tank.  

4. 

SAFETY INFORMATION

 

4.1. 

Safety regulations 

 

Read the "User Manual" carefully before start-up and use or before performing 

maintenance or any other work on the machine.  

 IMPORTANT 

Rigorously respect all instructions in the Manual (in particular those relating to 

danger and important information) and on the safety plates fitted to the machine.  

The Manufacturer declines all liability for damage to people or things resulting from 

failure to observe the instructions.  

The  appliance  must  be  used  exclusively  by  persons  trained  in  its  use  and/or  who  have 
demonstrated their ability and have been expressly instructed to use the appliance. 
The machine must not be used by minors.  
The machine must not be used for purposes other than those for which it was expressly 
designed.  Scrupulously respect all safety standards and conditions applicable to the type 
of  building  in  which  the  machine  is  to  be  operated  (e.g.:  pharmaceutical  companies, 
hospitals, chemicals, etc). 

 

Do not use the machine in places with inadequate lighting or explosive atmospheres, on 
public roads, in the presence of dirt hazardous to health (dust, gas, etc) and in unsuitable 
environments.  
The machine is designed for temperatures of b4°C and +35°C when in use and 
b0°C and +50°C when not in use. 
The machine is designed to work in a humidity of between 30% and 95%. 
Never use or pick up flammable liquids or explosives (e.g. petrol, fuel oil, etc), flammable 
gases,  dry  dusts,  acids  and  solvents  (e.g.  paint  solvents,  acetone  etc)  even  if  diluted.  
Never pick up flaming or incandescent objects.  
Never use the machine on slopes or ramps of more than 2%. In the case of slight slopes, 
do  not  use  the  machine  transversally,  always  manoeuvre  with  care  and  do  not  reverse.  
When transporting the machine on steeper ramps or slopes, take the utmost care to avoid 
tipping  up  and/or  uncontrolled  acceleration.    Move  the  machine  on  ramps  and/or  steps 
only with the brush head and squeegee raised.  
Never park the machine on a slope. 

Содержание CT110ECS

Страница 1: ...OPERATIONS MANUAL CT40ECS CT70ECS CT110ECS...

Страница 2: ...11 6 PRACTICAL GUIDE FOR THE OPERATOR 11 6 1 CONTROLS DESCRIPTION 11 6 2 MOUNTING AND ADJUSTING THE SQUEEGEE 13 6 3 MOVING THE MACHINE WHEN NOT IN OPERATION 13 6 4 MOUNTING AND CHANGING THE BRUSH DRI...

Страница 3: ...ENGLISH 3 10 TROUBLESHOOTING 21 10 1 HOW TO RESOLVE POSSIBLE PROBLEMS 21...

Страница 4: ...tes the need for attention in order to avoid a series of consequences which could cause death or damage to the health of the operator IMPORTANT Indicates the need for attention in order to avoid a ser...

Страница 5: ...ided with a special mechanical drive device which exploits the friction between the brush and the floor to generate a forward movement for further details see paragraph 6 7 MODEL BT electric drive the...

Страница 6: ...ained in its use and or who have demonstrated their ability and have been expressly instructed to use the appliance The machine must not be used by minors The machine must not be used for purposes oth...

Страница 7: ...nsable to respect the battery manufacturer s instructions and current legislation The batteries should always be kept clean and dry to avoid surface leakage current Protect the batteries from impuriti...

Страница 8: ...ifting and transporting the packaged machine IMPORTANT During all lifting operations make sure the packaged machine is firmly anchored to avoid it tipping up or being accidentally dropped Always load...

Страница 9: ...d 240 V Similarly models rated at 115 V can be used at between 110 V and 120 V The frequency on the plate must always correspond to the mains voltage IMPORTANT Make sure the mains circuit is suitably...

Страница 10: ...ws remove the caps and fill all elements with specific sulphuric acid solution until the plates are entirely covered this requires at least a couple of passes for each element leave for 4 5 hours to a...

Страница 11: ...he machine you must fit it with the connector supplied with the machine see paragraph Unpacking of this manual To install the connector proceed as follows remove about 13 mm of protective sheath from...

Страница 12: ...and rotates the brushes Squeegee lever fig 6 ref 8 raises when lifted or lowers when pushed down the squeegee Direction adjustment knob fig 6 ref 10 turn to correct any deviation of the machine from...

Страница 13: ...achine forwards press the button fig 6 ref 13 LED fig 6 ref 14 on and then operate the drive lever fig 6 ref 7 To move the machine backwards press the button fig 6 ref 13 again LED fig 6 ref 12 on the...

Страница 14: ...y Follow the safety regulations on use of detergents given in the section Safety regulations 6 6 Preparing the machine for work IMPORTANT Before starting work wear overalls ear protectors non slip wat...

Страница 15: ...lation knob fig 6 ref 10 If the machine pulls to the right turn the knob clockwise and vice versa Versions with electric drive to move forwards or backwards see paragraph 6 3 In both versions periodic...

Страница 16: ...brushes or drive disks to prevent them from warping permanently press the button to turn the optional CHEM DOSE accessory off fig 15 ref 2 depending on the model unplug the machine or disconnect the...

Страница 17: ...e suction filter fig 10 ref 2 from its housing and never direct the jet of water against the filter itself You are then ready to wash and dry again 6 10 Draining the clean water DANGER Use suitable pe...

Страница 18: ...not explicitly described in this manual must be performed by specialised personnel only in compliance with current safety legislation and as described in the maintenance manual 9 1 Maintenance General...

Страница 19: ...by completely unscrewing the two knobs fig 7 ref 3 remove the suction hose sleeve fig 7 ref 4 from the squeegee release the catch fig 12 ref 3 or 6 remove the two blade retainers fig 12 ref 2 or 7 by...

Страница 20: ...If necessary remove encrusted dirt Battery model recharge the batteries according to the procedure described 9 3 2 Weekly operations Clean the dirty water drum float switch and make sure it is workin...

Страница 21: ...ply or motor thermal cutout connectors are disconnected B BT reconnect the power supply or motor thermal cutout connectors C the motor power supply connector is disconnected C reconnect the motor powe...

Страница 22: ...switch has tripped dirty water drum is clogged by dirt or broken empty the dirty water drum or reset the float switch the suction hose is blocked unblock the hose the suction hose is not connected to...

Страница 23: ...ly the battery is new and does not deliver 100 of its expected capacity the battery must be run in by performing 20 30 charges and discharges to obtain maximum performance the machine is being used at...

Страница 24: ...ger are correct consult the battery charger manual the battery charger is not working make sure there is voltage to the battery charger that the fuses are not blown and that the current reaches the ba...

Страница 25: ...tions with a slow flash are cancelled automatically once the malfunction has been repaired and the machine functions normally again Malfunctions with a rapid flash in the table are considered more ser...