DAILY MAINTENANCE
1)
Always keep the machine clean inside and out.
2)
Pour 2 gallons of clean hot water in the solution tank. Turn on and flush the entire system through the wand
nozzles for about a minute to prevent build-up.
3)
Remove dirt and lint build-up inside the filter screen in the recover tank. Lint should be cleaned off so that
air flow is not impeded.
4)
Check the solution tank strainer in the solution tank. If lint has accumulated in the screen, remove and rinse
it in clear running water.
PERIODIC MAINTENANCE
All IPC machines are engineered and built to require a minimum of maintenance. But like any machine, it does
require some care to keep it in optimum working condition. Careful attention to these maintenance instructions
will give you maximum operating performance and will increase the life expectancy of your machine.
•
Solution Lines and Fittings: Flush the machine at least once a month with a solution of 3 parts water with 1
part white vinegar in order to neutralize the alkaline residue left by the cleaning solution.
•
Quick Connect Coupler: Spray with WD-40 or equivalent lubricant to prevent coupler from sticking.
•
Drain Valve: Apply light oil on gate seals. If machine has to be stored, leave the gate valve open.
•
Solution Pump: The same above procedure used on the solution line and fittings applies to the pump.
https://harrissupplyind.com - To Order Parts Call 608-268-8080