BEFORE OPERATING THE MACHINE 

Read the manual carefully and completely before attempting to operate the unit. This manual has important 
information for the use and safe operation of the machine. Keep this manual handy at all times. This machine 
will assure years of satisfactory service if operated and maintained according to recommendations in this 
manual. If additional information is needed, please contact your local distributor or write to: 

IPC EAGLE  

3650 Dodd Rd.

 

Eagan, MN 5512

3

 

WARNING 

The machine was designed for use on carpet, floor and upholstery extraction applications as per instructions
and recommendations written in this manual. Any deviation from its proper use or purpose and the
consequential damage that may occur is the sole responsibility if the end user.

Disconnect the power cord from the outlet before servicing. Do not leave machine connected to an electrical
outlet when unattended.

Do not immerse or use this machine in standing water. Such use may cause electric shock.

This equipment is not designed to handle or use combustible/volatile substances such as gasoline or
kerosene, in, on, or near the machine. The use of such materials will cause extreme hazardous condition.

When using an extension cord, use only a 3-prong conductor grounding cord- 12 ga. wire or heavier.

To avoid electric shock, do not expose the unit to rain. Store it indoors only.

Do not use the machine for dry vacuuming.

Use defoamer at all times to prevent damage to the vacuum motor(s).

Do not use water in excess of 170ºF (76ºC).

To prevent seal damage and chemical build-up to the pump system, run clean water through the solution
lines after each day’s use.

Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of
this type. Do not use dyes, bleaches, ammonia, or other additives. The use of powdered cleaning solution if
not diluted properly may result in damage to the pump. If powdered chemicals are used, premix in a
separate container before placing in the solution tank.

Do not expose machine to freezing temperatures.

All repairs must be done by an authorized IPC repair station.

Do not use replacement parts other than those specified on the parts list.

For units with 

HEAT’N’RUN 

heater:  

Read and understand the HEAT’N’RUN owners manual before using the HEAT’N’RUN heater on your
FASTRACT Extractor.

Do not run heater dry.

Water hookups must be in place and water flowing through the heater prior to turning it on. Failure to do so
may cause internal component damage and will void warranty

Heater must be filled with water or water based solutions at all times when in use. Turn off the switch and
unplug the heater from outlet when not in use.

Do not use heater at more than 500 PSI

Do not immerse heater in water

To avoid explosion and / or fire, do not use solvents or any flammable liquid in heater.

FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTIONS WILL VOID THE WARRANTY 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание BX12

Страница 1: ...NUAL PARTS LIST BX12 BX12H Fastracts Extractor IPC Eagle 3650 Dodd Rd Eagan MN 55123 800 486 2775 www ipceagle com h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2...

Страница 2: ...ng Use defoamer at all times to prevent damage to the vacuum motor s Do not use water in excess of 170 F 76 C To prevent seal damage and chemical build up to the pump system run clean water through th...

Страница 3: ...Instructions for FASTRACT with a HEATER 1 Be sure to fill the solution tank with water before plugging in the machine 2 Water hookups must be in place and water flowing through the heater prior to tu...

Страница 4: ...f it calls for dry cleaning do not attempt to clean by wet extraction otherwise damage to the fabric could occur Extraction works perfectly on most synthetic fabrics including synthetic velvets Before...

Страница 5: ...hine it does require some care to keep it in optimum working condition Careful attention to these maintenance instructions will give you maximum operating performance and will increase the life expect...

Страница 6: ...2 21 20 28 29 30 31 32 33 34 35 36 38 37 32 39 40 41 42 43 44 45 47 48 7 8 19 27 49 16 25 BX12 Upper IPC 18 17 24 26 5 A 5 D 5 C 5 B 50 46 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P...

Страница 7: ...E010453 GASKET SWITCH BRACKET 1 24 B00177 1 TERMINAL LUG FEMALE QD 25 X 032 4 25 B00185 30 WIRE 14 GA WHITE UL1015 5 IN 1 26 C02315 LOCKWASHER 10 INT STR SS 2 27 C00264 NUT 10 32 1 28 C11141 SCREW AL...

Страница 8: ...8 55 39 40 45 46 47 46 48 49 50 7 51 52 54 56 57 58 59 62 54 6 17 7 63 64 65 66 32 33 42 41 7 15 31 60 61 23 53 BX12 Base IPC 36 1 14 19 18 29 43 44 55 6 35 30 5 10 h t t p s h a r r i s s u p p l y i...

Страница 9: ...R MOUNTING PLATE 1 33 C11440 SPACER HEATER MOUNTING PLATE 4 34 A00061 3 8 BARB X 1 4 FP BRASS 1 35 H02564 2 LABEL CAUTION MOTOR HOUSING 1 36 C11165 SCREW 8 X 1 IN PAN BLACK 4 37 F11790 HEATER TUNNEL C...

Страница 10: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Отзывы: