background image

 IP-Link Installation Guide        

7

Operator Interface 

Connecting the Network

9 Pin

Female

End

Connect Ethernet RJ 45 Cable

Assembly To

Port

On IP-Link

-

10/100Base-T

9 Pin

Female

Connector

9 Pin

Female

Connector

Molded

Cable Assembly

Supplied With

IP-Link Kit

9 Pin Male End

Connect To Serial

Port On IP-Link

25 Pin

Female

Connector

(If Reqd)

Connection To Computer

Serial Port

(Optional. See Note 1.)

Personal Computer

(Optional, By Others. See Note 1)

Connect Supplied 6 Ft. Ethernet RJ-45

Cable Assembly Or Longer Ethernet RJ-45 Cable

(Supplied By Others) To

ase

Connection

On Ethernet Router Or Modem (Supplied By Others)

10/100B

-T Port

Back View of CommLink

Back View of IP-Link

Top View of IP-Link

Front View of IP- Link

C

L

II

omm ink

LOOP

24V

T G R

GND

REMOTE LINK

(DTE)

COMPUTER

(DCE)

485

LOOP

STATUS

POW

ER

COM

P

RLINK

SERIAL #

C

O

N

T

R

O

L

S

8 Conductor

Modular Cable

Assembly

110 VAC To

9 VDC

Power Pack

110 VAC To

24 VAC

Power Pack

SHLD

T

R

Typical Terminal Blocks. All
Wiring To Be T To T, SHLD (G)
To SHLD (G) & R To R

T G R

485

LOOP

Computer Connection Diagram Using IP-Link For Remote Connection

Front View of CommLink

CommLink II

C

onnect

ne

For Orion Systems Connect To MiniLink PD Network Terminals
For WattMaster VAV Systems Connect To MiniLink Network Terminals
For Auto-Zone Systems Connect To MiniLink Network Terminals
For WattMaster WHP Systems Connect To MiniLink Network Terminals

Wire To Be 2 Conductor Twisted

Pair With Shield. Use Belden
#82760 Or Equivalent.

iLAN-100

10/100BASE-T

LINK

ACT

SNET

POWER

MODE

PWR

SERIAL

Notes:

1.) Direct Connection From The Computer Serial Port To The CommLink II Is Not Required But It May Be
Connected If Desired. Communication With The Control System Is Available Through The IP-Link Ethernet
Connection To The Building LAN By Any Computer on The LAN Via The IP-Link’s Ethernet IP Address.

2.) You Must

The

II

3.) You Must

The

II

The

The

Set

CommLink

Internal Switch To “Multi” For All Applications.

Replace

CommLink

EPROM (SS0039) With

IP-Link EPROM (SS0058) Supplied

With

IP-Link Kit.

IP-Link

OE415

www

.wattmaster

.com

Figure 8: Computer Connection Using the IP-Link

Содержание iLAN-100

Страница 1: ...IP Link Installation Guide www wattmaster com 10 100BASE T LINK ACT S N E T P O W E R M O D E P W R S E R I A L I P L i n k O E 4 1 5 w w w w a t t m a s t e r c o m...

Страница 2: ...One and iLAN are registered trademarks of Connect One Ltd WattMaster Controls Inc assumes no responsibility for errors or omissions This document is subject to change without notice General Informati...

Страница 3: ...to allow traffic to and from this device The nature of the data is raw in form and comprised of packets native to Prism software The IP Link will respond to ICMP traffic PING for verification of prop...

Страница 4: ...g it to the power supply cable 5 Insert the CD in the CD drive of your PC Run the Setup exe in the Software directory to install the configuration software Installing and Starting the iChip Config Pro...

Страница 5: ...on If the Firmware version and Boot Block are current enter the IPAddress and Subnet Mask Leave the Use DHCPand Use IP Finder boxes clear and the rest of the form blank The IP Link doesn t require any...

Страница 6: ...the back of the IP Link and to the Remote Link or DTE port on the back of the CommLink II After powering up the two devices units will establish communication and there will be rapid and continuous a...

Страница 7: ...nal Blocks All Wiring To Be T To T SHLD G To SHLD G R To R T G R 485 LOOP Computer Connection Diagram Using IP Link For Remote Connection Front View of CommLink CommLink II Connect ne For Orion System...

Страница 8: ...et Cable To Other Nodes On Building LAN Or WAN Ethernet Cable 18 Gauge 2 Conductor Twisted Pair With Shield Cable 18 Gauge 2 Conductor Twisted Pair With Shield Cable Serial Cable WattMaster Control Sy...

Страница 9: ...OTE Make sure that the IP Link is connected as shown in Figure 8 and all installation procedures have been com pleted prior to using the telnet command To do this open a DOS session by opening a comma...

Страница 10: ...100 capable which allows greater flexibility when connecting to an existing network Appendix 3 There is no longer a RCV and SER LED on the unit As a result in order to verify communication between the...

Страница 11: ...IP Link Installation Guide 11 Operator Interface Notes...

Страница 12: ...WM IPLNK TGD 01B Printed in the USA July 2007 All rights reserved Copyright 2007 WattMaster Controls Inc 8500 NW River Park Drive Parkville MO 64152 Phone 816 505 1100 www wattmaster com Fax 816 505...

Отзывы: