Notes on the IP-Link 

 The IP-Link is functionally the same 

as the previous version with a few small differences.

1.    There are only two LEDs on the unit indicating a 

LINK condition on the Ethernet and Activity on the 
same link. 

2.    The Ethernet Port is now 10/100 capable which

allows greater fl exibility when connecting to an
existing network. 

Appendix

3.   There is no longer a RCV and SER LED on the unit. 

As a result, in order to verify communication between 
the CommLink II and the IP-Link, the installer will 
have to observe the RLINK LED on the CommLink 
II. The LED will be lit but will display a rapid but 
faint fl icker if proper communication is established. 
Verifi cation of an active address by PING or telnet 
procedures stated previously will also prove proper 
operation. 

Содержание iLAN-100

Страница 1: ...IP Link Installation Guide www wattmaster com 10 100BASE T LINK ACT S N E T P O W E R M O D E P W R S E R I A L I P L i n k O E 4 1 5 w w w w a t t m a s t e r c o m...

Страница 2: ...One and iLAN are registered trademarks of Connect One Ltd WattMaster Controls Inc assumes no responsibility for errors or omissions This document is subject to change without notice General Informati...

Страница 3: ...to allow traffic to and from this device The nature of the data is raw in form and comprised of packets native to Prism software The IP Link will respond to ICMP traffic PING for verification of prop...

Страница 4: ...g it to the power supply cable 5 Insert the CD in the CD drive of your PC Run the Setup exe in the Software directory to install the configuration software Installing and Starting the iChip Config Pro...

Страница 5: ...on If the Firmware version and Boot Block are current enter the IPAddress and Subnet Mask Leave the Use DHCPand Use IP Finder boxes clear and the rest of the form blank The IP Link doesn t require any...

Страница 6: ...the back of the IP Link and to the Remote Link or DTE port on the back of the CommLink II After powering up the two devices units will establish communication and there will be rapid and continuous a...

Страница 7: ...nal Blocks All Wiring To Be T To T SHLD G To SHLD G R To R T G R 485 LOOP Computer Connection Diagram Using IP Link For Remote Connection Front View of CommLink CommLink II Connect ne For Orion System...

Страница 8: ...et Cable To Other Nodes On Building LAN Or WAN Ethernet Cable 18 Gauge 2 Conductor Twisted Pair With Shield Cable 18 Gauge 2 Conductor Twisted Pair With Shield Cable Serial Cable WattMaster Control Sy...

Страница 9: ...OTE Make sure that the IP Link is connected as shown in Figure 8 and all installation procedures have been com pleted prior to using the telnet command To do this open a DOS session by opening a comma...

Страница 10: ...100 capable which allows greater flexibility when connecting to an existing network Appendix 3 There is no longer a RCV and SER LED on the unit As a result in order to verify communication between the...

Страница 11: ...IP Link Installation Guide 11 Operator Interface Notes...

Страница 12: ...WM IPLNK TGD 01B Printed in the USA July 2007 All rights reserved Copyright 2007 WattMaster Controls Inc 8500 NW River Park Drive Parkville MO 64152 Phone 816 505 1100 www wattmaster com Fax 816 505...

Отзывы: