Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE

 

Page 10/20

 

UMA-CDZ-IP-ACIRM100-00

 

Upstream of the electrical connection, an efficient disconnection 
system must be provided and it must be clearly identified 
 
Air  conditioner  is  already  fitted  with  a  temperature  controller, no 
additional  temperature  control  must  be  connected  upstream  of 
the unit. 

 

4 - STARTING AND ADJUSTMENT 

 

4.1  GENERAL DESCRIPTION 

 

Air  conditioners  are  especially  designed  for  dissipation  of  heat  loss  inside  electrical 
enclosures with IP54 protection degree. 
Air  circulation  inside  the  enclosures  allows  to  keep  enclosure  air  volume  isolated  from 
external  ambient  air,  it  preserves  the  inside  of  the  enclosure  against  dirt  and  humidity 
which are present in the external air. 

 

IP-ACIRM  series  must  be  installed  only  on  the  roof  of  electrical 
enclosure  

 

After  finishing  assembly  of  the  conditioner,  wait  approx.  30  min. 
before starting it (the oil must collect in the compressor to ensure 
lubrication and cooling). 

The air conditioner operates automatically, that is to say, after insertion, the evaporator fan 
operates  continuously  making  the  air  inside  the  cabinet  circulate.  This  way  a  uniform 
distribution  of  temperature  inside  the  cabinet  itself  is  attained.  The  built-in  thermostat 
drives compressor and condenser fan according to set point value and other parameters 
(See  PARAMETERS  at 

4.2  DIGITAL  THERMOSTAT  INSTRUCTION

 

section  for 

references)  

 

Compressor and condenser fan start after a delay set on thermostat (see parameter AC on 
parameters list for references) to permit a

 

minimum interval between the compressor stop 

and the following restart.  

  

During  proper  operations,  the  compressor  and  condenser  fan 
turn  OFF  when  internal  enclosure  temperature  decreases  under 
set point value. 

Содержание IP-ACIRM100

Страница 1: ...00 00 USER S MANUAL PART 2 ROOF MOUNT AIR CONDITIONER FOR ELECTRICAL ENCLOSURE INDOOR APPLICATION IP ACIRM100 Document UMA CDZ IP ACIRM100 00 Date Name Description Original user s manual for air condi...

Страница 2: ...closure there must not be components that could affect the proper ventilation Provide a proper fixing of the electrical enclosure to the floor to prevent accidental tipping due to the supplementary we...

Страница 3: ...ES Unit Power supply V ph Hz 230 1 50 60 Cooling capacity EN14511 A35 A35 W 1000 1060 A35 A50 W 760 790 Absorbed electric power EN14511 A35 A35 W 780 810 A35 A50 W 890 930 Rated current A 5 1 6 2 Moto...

Страница 4: ...Electrical enclosure must be sized according to air conditioner dimensions and weight Electrical enclosure must have at least IP54 protection degree Internal and external components of electrical encl...

Страница 5: ...hole on the enclosure as is shown in the drilling template VIEW FROM EXTERNAL OF ELECTRICAL ENCLOSURE Deburr all sharp edges to avoid accidental injuries 2 Apply the gasket included in fixing kit on t...

Страница 6: ...ipes in order to ensure proper drainage in case of occlusion of a drain pipe Air conditioner produces condensate because the moist air inside of the enclosure meets cold heat exchanger evaporator and...

Страница 7: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 7 20 UMA CDZ IP ACIRM100 00 3 ELECTRICAL CONNECTION 3 1 WIRING DIAGRAM...

Страница 8: ...andard Before the installation make sure that the cabinet is disconnected from the electrical supply Wire male plug included with an adequate cable as is shown by following picture Cable section must...

Страница 9: ...larm output is activated according to alarm parameters for example in case of enclosure temperature higher than ALU value digital input not activated See PARAMETERS at 4 2 DIGITAL THERMOSTAT INSTRUCTI...

Страница 10: ...lled only on the roof of electrical enclosure After finishing assembly of the conditioner wait approx 30 min before starting it the oil must collect in the compressor to ensure lubrication and cooling...

Страница 11: ...ions for parameter changing To display target set point in programming mode it selects a parameter or confirm an operation DEF To start a manual defrost To see the max stored temperature in programmin...

Страница 12: ...SET key or wait for 5 seconds to display the probe value again 4 2 5 HOW TO CHANGE THE SETPOINT 1 Push the SET key for more than 2 seconds to change the Set point value 2 The value of the set point w...

Страница 13: ...defrost cycles 0 120h Determines the time interval between the beginning of two defrost cycles MdF Maximum length for defrost 0 255min 0 no defrost When P2P n not evaporator probe timed defrost it set...

Страница 14: ...as the external digital input is disabled again With the door open the high and low temperature alarms are disabled Digital inputs polarity The digital input polarity depends on the i1P parameter i1P...

Страница 15: ...Ht heating cL Pr1 rES Resolution in integer dE dec point dE Pr1 IdF Interval between defrost cycles 1 120 hours 8 Pr1 MdF Maximum length for defrost 0 255 min 0 Pr1 ALU MAXIMUM temperature alarm Set...

Страница 16: ...ESCRIPTION CODE 1 Evaporator fan VCENT190D230V 2 Compressor COMPRSC12G 3 Condenser fan VCENT220D230U C1 Evaporator fan capacitor CON2UFS2M8F C3 Condenser fan capacitor CON2UFS2M8F 4 Regulating thermos...

Страница 17: ...oling circuit has been modified about type and quantity of refrigerant or composition 2 the unit operates in acid or corrosive ambient 3 the unit has been modified without IP ENCLOSURES consent This w...

Страница 18: ...UE LOW VOLTAGE DIRECTIVE 26 February 2014 2014 30 UE EMC DIRECTIVE 26 February 2014 2011 65 UE ROHS DIRECTIVE 8 June 2011 STANDARDS APPLIED TO MEET THE PRINCIPAL ELEMENTS OF THE DIRECTIVE EN 60335 2 4...

Страница 19: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 19 20 UMA CDZ IP ACIRM100 00 SAA CERTIFICATE...

Страница 20: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 20 20 UMA CDZ IP ACIRM100 00 NOTES...

Отзывы: