2.4 IEEE 488 Bus Implementation
The Digital488HS/32 implements many of the capabilities defined by the IEEE 488.1
specification. These are discussed in the following sections. The bus uniline and
multiline commands the Digital488HS/32 does not support or respond to include the
following:
Remote Enable (REN)
Parallel Poll Configure (PPC)
Go to Local (GTL)
Parallel Poll Unconfigure (PPU)
Local Lockout (LLO)
Parallel Poll Disable (PPD)
Take Control (TCT)
2.4.1 My Talk Address (MTA)
When the Digital488HS/32 is addressed to talk, it outputs any data available on the
Digital Input Port. If the interface has been Serial Poll Enabled (SPE) by the
controller, it responds with its serial poll status byte until Serial Poll Disabled (SPD).
2.4.2 My Listen Address (MLA)
When the Digital488HS/32 is addressed to listen, it accepts characters from the active
talker and outputs them without interpretation to the Digital Output Port. The
Digital488HS/32 is not software programmable, so it does not accept any device
dependent commands.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com