IonWays RO System Скачать руководство пользователя страница 9

©Copyright 2009 IonWays, LLC VS.1 

Page 9 

 

PERFORMANCE DATA SHEET 

 

Function: 

Arsenic Reduction 

 

 

 

    

Cadmium Reduction 

 

 

 

Cyst Reduction   

 

 

 

Hexavalent Chromium Reduction 

 

Radium 226/228 Reduction 

 

 

TDS Reduction   

 

 

 

Barium Reduction 
Copper Reduction 
Fluoride Reduction 
Lead Reduction 
Selenium Reduction 
Trivalent Chromium Reduction 
 
 
While testing was performed under standard laboratory conditions, actual performance may vary.  
 

General Installation /Operation/Maintenance Requirements  

 

 

Installation needs to comply with state and local laws and regulations 

 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 
before or after system. Systems certified for cyst reduction may be used on disinfected water that may 
contain filterable cysts.  

 

This reverse osmosis system contains a replaceable treatment component critical for effective reduction 
of total dissolved solids. The product water shall be tested periodically to verify that system is performing 
satisfactorily.  

 

 

 

PERFORMANCE DATA SHEET REQUIREMENTS 

Substance 

Influent challenge 

Concentration mg/L 

Maximum permissible product 

Water concentration mg/L 

Average Percent 

Reduction 

Arsenic 

(pentavalent) 

0.30 ± 10% 

 

0.010 

99.3% 

Barium 

10.0 ± 10% 

2.0 

98.5% 

Cadmium 

0.03 ± 10% 

0.005 

98.1% 

Chromium 

(hexavalent) 

              0.3 ± 10% 

0.1 

97.7% 

Chromium 

(trivalent) 

 0.3 ± 10% 

0.1 

99% 

Copper 

 0.3 ± 10% 

1.3 

98.7% 

Fluoride  

 8.0 ± 10% 

1.5 

95.5% 

Lead 

            0.15 ± 10% 

0.010 

98.1% 

Radium 226/228 

25 pCi/L ± 10% 

5pCi/L 

80% 

Selenium 

0.1 ± 10% 

0.05 

>94% 

TDS 

750 ± 40 mg/L 

187 

 

System tested and certified by WAQ against NSF/ANSI 
Standard 58 for the reduction of Arsenic, Barium, Copper, 
Cyst, Fluoride, Hexavalent Chromium, Lead, Radium 
226/228, Selenium, TDS, Trivalent Chromium

 

Conforms to NSF/ANSI 58 for pentavalent arsenic  
Reduction. See performance data sheet and Arsenic Facts 
section for an explanation.  

 

Содержание RO System

Страница 1: ...sis Drinking Water System Includes Remineralization System tested and certified by WQA against NSF NSI Standard 58 for the reduction of Arsenic Barium Copper Cyst Fluoride Hexavalent Chromium Lead Rad...

Страница 2: ...valve feed water valve faucet assembly 5 Manual and warranties 6 Optional Undersink Kit Sold Separately Optional Under Sink Kit Sold Separately RECOMMENDED TOOLS LIST Variable speed drill 1 8 and 1 4...

Страница 3: ...talled on top of the counter IonWays also offers an optional double spouted faucet that is fed from the ionizer installed under the sink If you are using the double spouted faucet do not use the blue...

Страница 4: ...obium Osmium Palladium Potassium Praseodymium Rhenium Rhodium Rubidium Ruthenium Samarium Scandium Sodium Strontium Tantalum Tellurium Terbium Thallium Vanadium Yttrium Zirconium Fitting Installation...

Страница 5: ...out of faucet with angle valve turned off the house main will have to be turned off Care must be taken for appliances that may be damaged by an interrupted water supply 2 Easy Connector Cold Water Sup...

Страница 6: ...alve off Mounting the Drain Clamp The drain clamp VV DSP014 3 will fit most standard drain pipe 1 1 4 It should be installed above the trap and on the vertical tailpiece 1 Position the drain saddle in...

Страница 7: ...r as a replacement for the flexible stainless steel tube Do not over tighten if needed use Teflon tape 3 Push the larger sized opening on the 90 o Acid Spout fitting onto the Acidic Water Outlet 4 Ins...

Страница 8: ...ete 7 After the second tank is filled turn on the ionizer and allow it to purge by running it for one minute before getting a glass of water 8 Check for leaks daily for the first week and periodically...

Страница 9: ...ains a replaceable treatment component critical for effective reduction of total dissolved solids The product water shall be tested periodically to verify that system is performing satisfactorily PERF...

Страница 10: ...arsenic from water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment...

Страница 11: ...n fouling with sediment or scale or failure to operate the system in accordance with the instructions contained in the owner s manual 2 The following operating conditions must also be followed for thi...