©Copyright 2009 IonWays, LLC VS.1
Page 9
PERFORMANCE DATA SHEET
Function:
Arsenic Reduction
Cadmium Reduction
Cyst Reduction
Hexavalent Chromium Reduction
Radium 226/228 Reduction
TDS Reduction
Barium Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Selenium Reduction
Trivalent Chromium Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
General Installation /Operation/Maintenance Requirements
•
Installation needs to comply with state and local laws and regulations
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after system. Systems certified for cyst reduction may be used on disinfected water that may
contain filterable cysts.
•
This reverse osmosis system contains a replaceable treatment component critical for effective reduction
of total dissolved solids. The product water shall be tested periodically to verify that system is performing
satisfactorily.
PERFORMANCE DATA SHEET REQUIREMENTS
Substance
Influent challenge
Concentration mg/L
Maximum permissible product
Water concentration mg/L
Average Percent
Reduction
Arsenic
(pentavalent)
0.30 ± 10%
0.010
99.3%
Barium
10.0 ± 10%
2.0
98.5%
Cadmium
0.03 ± 10%
0.005
98.1%
Chromium
(hexavalent)
0.3 ± 10%
0.1
97.7%
Chromium
(trivalent)
0.3 ± 10%
0.1
99%
Copper
0.3 ± 10%
1.3
98.7%
Fluoride
8.0 ± 10%
1.5
95.5%
Lead
0.15 ± 10%
0.010
98.1%
Radium 226/228
25 pCi/L ± 10%
5pCi/L
80%
Selenium
0.1 ± 10%
0.05
>94%
TDS
750 ± 40 mg/L
187
System tested and certified by WAQ against NSF/ANSI
Standard 58 for the reduction of Arsenic, Barium, Copper,
Cyst, Fluoride, Hexavalent Chromium, Lead, Radium
226/228, Selenium, TDS, Trivalent Chromium
Conforms to NSF/ANSI 58 for pentavalent arsenic
Reduction. See performance data sheet and Arsenic Facts