System Start Up
1.) Turn on the cold water supply and the under sink feed water valve (VV-WNV-4) but close the tank ball
valve (VV-BLP014WJG).
2.) Open double spouted faucet (FU-WDF-103-3NSF) for continuous flow.
3.) Check system for leaks. Tighten as necessary.
4.) After 10-30 minutes, the water will start to drip out of the RO faucet. Let it drip for about 10 minutes and
then flip the handle to the closed position.
TURN ON THE TANK BALL VALVE NOW
. It will now take
several hours (2-3) for the storage tank to fill, depending on the local water pressure.
DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY YOUR NEWLY PURCHASED
SYSTEM!
5.) After the tank is full, you will notice that the water stops. Flush the system by placing the double spouted
faucet in the open position until the water is completely discharged (leave ionizer turned off).
6.) Upon complete discharge of storage tank, flip handle to closed position of the faucet and let the refilling
process begin. This process could take 2-3 hours to complete.
7.) After the second tank is filled, turn on the ionizer and allow it to purge by running it for one minute before
getting a glass of water.
8.) Check for leaks daily for the first week and periodically thereafter.
9.) You may notice that the water may be milky colored during the first week. It is the air bubbled in the
water. It is normal and safe.
NOTE:
1.) Do not use RO System with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.
2.) This reverse osmosis system contains a replaceable component critical to the efficiency of the
system. Replacement of the reverse osmosis component should be with one of identical
specifications, as defined by the manufacturer, to assure the same efficiency and contaminant
reduction performance.
3.) IonWays accepts no responsibility for any consequences that arise due to the installation
process.
Item #
Description
802
RO Tank
803
RO Sediment Cartridge
804
RO Carbon Cartridge
805
RO Membrane
806
RO Remineralizer Cartridge
WARNING: Never use hot water or allow unit to freeze
.
WARNING: Incorrect installation will VOID the warranty.