ALF-13120-E-02
All-Flo
14
AIR VALVE REMOVAL
STEP 1
Rotate the “Intermediate” to the
exhaust muffler side.
STEP 2
Using the 1/4 wrench (or straight
blade screwdriver) remove six
“Screws” from the “Muffler Plate”.
Note the center two “Screws”
should not be removed.
STEP 3
Stabilize the “Air Valve”
mechanism to prevent it from
shifting. Move the mechanism
to the “Hard Stop” position. See
Step 4-5.
TOOLS NEEDED
1) One Wrench, 1/4 Inch
2) One Screwdriver, Straight Blade
3) One Hex Key,
7
/
64
Inch (3mm)
WARNING
Prior to servicing the pump, ensure that the air and fluid
lines are closed and disconnected. While wearing personal protective equip-
ment, flush, drain and process liquid from the pump in a safe manner.
WARNING
Maintenance must not be performed when a hazardous atmo-
sphere is present.
STEP 4
STEP 5
STEP 6
Remove the “Air Valve” from
the “Intermediate”. Set the
mechanism to the the “Hard Stop”
position.
REPAIR AND ASSEMBLY
CAUTION: Only one side of the valve mechanism has a hard-stop.
Shifting the mechanism past its operating position can cause the spring
to pop free and internal components to come loose. Use caution when
shifting the mechanism manually.