PERFORMANCE CURVES
PERFORMANCE CURVE
Performance Specifications
Max. Flow:
9 gpm (34.0 lpm)
Max. Air Pressure:
120 psi (8.2 bar)
Max. Solids:
1
/
4
” (6.4 mm)
Max. Suction Lift Dry:
17 ft-H
2
O (5.2 m-H
2
O)
Max. Suction Lift Wet:
26 ft-H
2
O (7.9 m-H
2
O)
Weight Polypropylene
& Conductive Nylon:
3.8 lbs (1.7 kg)
Weight PVDF:
5 lbs (2.3 kg)
Air Inlet:
1
/
4
” FNPT
Liquid Inlet FNPT/FBSPT:
3
/
8
”
Liquid Outlet FNPT/FBSPT:
3
/
8
”
Height:
7.19” (182.6 mm)
Width:
8.55” (217.2 mm)
Depth:
4.82” (122.4 mm)
5
SECTION
*Flow rates indicated on the chart(s) shown were determined by pumping water at flooded suction. For optimum life and performance, pumps should be
specified so that daily operation parameters will fall in the center of the pump performance curve.