1.2.0 firmware version). Depending on this choice, it will be possible to switch dynamically among two, four or
32 alternative preset configurations.
3.6.4 Inxpect Safety application usage
To use the application, the controller must be connected to a computer with a data micro-USB cable or an
Ethernet cable. The USB cable allows to configure the system locally, whereas the Ethernet cable allows to do
it remotely.
The Ethernet communication between the ISC-B01 and the Inxpect Safety application is secured by the most
advanced security protocols (TLS).
3.6.5 Dynamic configuration through the digital inputs
To activate the dynamic system configuration, one or both the digital inputs of the ISC-B01 controller can be
used. The result is the following:
If...
Then it is possible to dynamically switch
between...
only
one
digital input is used for the dynamic
configuration
two
preset configurations (see "Example 1" below
and "Example 2" below)
both
digital inputs are used for the dynamic
configuration
four
preset configurations (see "Example 3" below)
Example 1
The first digital input has been linked to the dynamic configuration.
Configuration
Input 1
Input 2
Dynamic configuration #1
0
-
Dynamic configuration #2
1
-
0 = signal deactivated; 1 = signal activated
Example 2
The second digital input has been linked to the dynamic configuration.
Configuration
Input 1
Input 2
Dynamic configuration #1
-
0
Dynamic configuration #2
-
1
0 = signal deactivated; 1 = signal activated
Example 3
Both digital inputs have been linked to the dynamic configuration.
Configuration
Input 1
Input 2
Dynamic configuration #1
0
0
Dynamic configuration #2
1
0
Dynamic configuration #3
0
1
Dynamic configuration #4
1
1
0 = signal deactivated; 1 = signal activated
3.6.6 Dynamic configuration through the safety Fieldbus
To activate the dynamic system configuration, connect an external safety PLC that communicates through the
safety Fieldbus to the ISC-B01 controller. This makes it possible to dynamically switch between all the preset
configurations, therefore up to 32 different configurations. For all the parameters used for each configuration,
see "Dynamic system configuration" on the previous page.
For details about the supported protocol, please refer to the Fieldbus manual.