iMars BD3KTL-PS Energy Storage Inverter Product overview
9
Symbol
description
TUV certification identification. The inverter obtains TUV certification.
CE certification identification. The inverter conforms to CE instruction.
CQC certification identification. The inverter obtains CQC certification
2.4 DRM instruction
Figure 2.3 DRM label
Table 2-2 DRMs instruction
No.
Mode
Requirement
1
DRM0
Operter the disconnection devise
2
DRM1
Do not consume power
3
DRM2
Do not consume at more than 50% of rated power
4
DRM3
Do not consume at more than 75% of rated power AND Source
reactive power if capable
5
DRM4
Increase power consumption(subject to constraints from other active
DRMs)
6
DRM5
Do not generate power
7
DRM6
Do not generate at more than 50% of rated power
8
DRM7
Do not generate at more than 75% of rated power AND Sink reactive
power if capable
9
DRM8
Increase power generation(subject to constraints from other active
DRMs)
Note: The inverter only realize the DRM0 function.