SHENZHEN INVT ELECTRIC CO., LTD. CHV160 Operation Manual
105
Function
Code
Name
Detail Parameter Description
Setting
Range
Defaul
t
Modifi
cation
LCD Display Serial
No.
Pb.11
Over-current Stall
Protection
0: Disabled
1: Enabled
0
1
0
OC Stall
Protect
245.
Pb.12
Over-current Stall
Protection Current
100
200%
100
200
150%
OC Stall
Current
246.
Pb.13
Over-current
Frequency Drop
Rate
0.00
50.00Hz/s
0.00
50.00
0.00H
z/s
OC freq
droprate
247.
PC Group Communication
PC.00
Local Inverter
Communication
Address
1-247, 0: broadcast address
1
247
1
Local comm
addr
248.
PC.01
Communication
baud rate setting
0
1200BPS
1
2400BPS
2
4800BPS
3
9600BPS
4
19200BPS
5
38400BPS
0
5
3
Baud rate
249.
PC.02
Data bit check
setting
0: Null (N
8
2)
1: Even (E
8
1)
2: Odd (O
8
1)
0
2
0
Bit check
250.
PC.03
Communication
response delay
0
20ms
0
20
0
Response
delay
251.
PC.04
Communication
overtime fault time
0.0
invalid
0.1
100.0s
0.0
100.0
0.0s
Comm
overtime
252.
PC.05
Reserved function
0
1
0
1
0
Reserved
253.
PC.06
Reserved function
0
65535
0
65535
0
Reserved
254.
PC.07
Reserved function
0
65535
0
65535
0
Reserved
255.
PC.08
Reserved function
0
65535
0
65535
0
Reserved
256.
PC.09
Reserved function
0
65535
0
65535
0
Reserved
257.
Pd Group Reserved Func
Pd.00
Reserved function
0
65535
0
65535
0
Reserved
258.
Pd.01
Reserved function
0
65535
0
65535
0
Reserved
259.
Pd.02
Reserved function
0
65535
0
65535
0
Reserved
260.
Pd.03
Reserved function
0
65535
0
65535
0
Reserved
261.
Pd.04
Reserved function
0
65535
0
65535
0
Reserved
262.