SHENZHEN INVT ELECTRIC CO., LTD. CHV160 Operation Manual
29
3. The set value of function code (the third-stage menu)
Remarks: when working at the third-stage menu, press Button PRG/ESC or Button
DATA/ENT to return to the second-stage menu. The difference between both is: pressing
Button PRG/ESC will save the set parameters into the control panel, and then return to the
second-stage menu and also automatically shift to the next function code; pressing Button
DATA/ENT will directly return to the second-stage menu without saving the parameters, and
keep staying at the current function code.
For example: change the function code P1.01 setting from 00.00Hz to 01.05Hz
Figure 5-2 Third Stages Menu Operation Process Diagram
Under the third stages menu, if the parameter has no flickering bit, it means this
parameter can not be modified. The possible reasons could be:
1) This parameter is unchangeable parameter, such as actual detected parameter,
operation records and so on;
2) This parameter is un-modifiable under operating state, but modifiable at stop state
5.2.2 Shortcut Menu
Shortcut menu, in which often used parameters can be put, provides a quick way to view
and modify function parameters. At the shortcut menu, a parameter being displayed as
“hP0.11”means it is the function parameter P0.11. Modifying parameters at the shortcut menu
has the same effect as doing at general programming state.
Maximum 16 function parameters can be put into the shortcut menu, and in the shortcut
menu parameter can be added and deleted when the function code F7-03 is set as 0.