![INVISIBLE FENCE Safe Dog Monitor Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/invisible-fence/safe-dog-monitor/safe-dog-monitor_installation-and-training-manual_2085339005.webp)
- DRAFT -
Rev. 1.0 JAB
5
G:\PCTEST LAB\2006 Reports\TRP\Safe Dog Monitor - Part 68\TCB Documents\KZ3-050808 manual.doc
Need Part Number
Sensor via a 900 MHz radio frequency signal. If an alert condition is detected, the Dialer Unit
initiates an alert notification to Invisible Fence, Inc. This alert notification is then sent via email to
the appropriate Invisible Fence Brand Distributor and Dealer.
[Picture of both the Loop Sensor and Dialer Unit]
For proper operation, the Loop Sensor and Dialer Unit should never be located more than 250 feet
apart (line of sight). The range may vary due to surrounding environmental conditions such as
physical obstructions. The Loop Sensor and Dialer Unit also need to be synchronized to each other
during installation (See page ___ for further instructions on RF Link Programming).
1.5 Loop Sensor User Controls
The Loop Sensor has a push button that is used for linking to the Dialer Unit, calibrating to the set
signal field, and re-setting to the default condition. [Show close up picture of Loop Sensor t-board
with call-out for the push button]
1. If the Loop Sensor is not linked to the Dialer Unit, and the push button is pressed for less than
two seconds
, the Loop Sensor will enter the RF Link Programming mode. The Loop Sensor
will remain in this mode until programming is complete or a period of fifteen seconds has
elapsed.
2. If the Loop Sensor is already linked to the Dialer Unit and the push button is pressed for less
than two seconds, the Loop Sensor will calibrate to the signal field. These values will be used
for determining the presence of a signal reduction/increase/loss/imbalance.
3. Pushing the button with for
more than 10 seconds
will reset the Loop Sensor to the default
condition.
1.6 Dialer Unit User Control
The Dialer Unit has a push button that is used for either entering the RF Link Programming mode or
re-setting to the initial default condition. [Show close up picture of Dialer t-board with call-out for
the push button and jumper switch]
1. If the push button is pressed for less than two seconds the Dialer Unit will enter the RF Link
Programming mode. The Dialer unit will remain in this mode until programming is complete
or until the RF Link Programming mode has failed.
2. Pushing the button with for
more than 10 seconds
will reset the Loop Sensor to the default
condition.
The Dialer Unit also is equipped with a “jumper switch” which can be used to test the RF Link during
product installation and set-up.
2.0 Planning the Safe Dog
®
Monitor Installation
Planning the location of the Safe Dog Monitor components is critical to proper operation and
providing a professional installation. Before permanently mounting any components (Loop Sensor or
Dialer Unit), verify proper operation. Please read all instructions contained in this manual before
installing the Safe Dog Monitor.
2.1 Safe Dog Monitor Loop Sensor
The Loop Sensor should be located on a flat wall surface near the Invisible Fence Brand transmitter.