Sensor via a 900 MHz radio frequency signal. If an alert condition is detected, the Dialer Unit 
initiates an alert notification to Invisible Fence, Inc.  This alert notification is then sent via email to 
the appropriate Invisible Fence Brand Distributor and Dealer. 
[Picture of both the Loop Sensor and Dialer Unit] 
 
For proper operation, the Loop Sensor and Dialer Unit should never be located more than 250 feet 
apart (line of sight).  The range may vary due to surrounding environmental conditions such as 
physical obstructions.  The Loop Sensor and Dialer Unit also need to be synchronized to each other 
during installation (See page ___ for further instructions on RF Link Programming). 
 

1.5 Loop Sensor User Controls 

The Loop Sensor has a push button that is used for linking to the Dialer Unit, calibrating to the set 
signal field, and re-setting to the default condition.  [Show close up picture of Loop Sensor t-board 
with call-out for the push button] 

1.  If the Loop Sensor is not linked to the Dialer Unit, and the push button is pressed for less than 

two seconds

, the Loop Sensor will enter the RF Link Programming mode.  The Loop Sensor 

will remain in this mode until programming is complete or a period of fifteen seconds has 
elapsed.  

2.  If the Loop Sensor is already linked to the Dialer Unit and the push button is pressed for less 

than two seconds, the Loop Sensor will calibrate to the signal field. These values will be used 
for determining the presence of a signal reduction/increase/loss/imbalance. 

3.  Pushing the button with for 

more than 10 seconds

 will reset the Loop Sensor to the default 

condition. 

 

1.6 Dialer Unit User Control 

The Dialer Unit has a push button that is used for either entering the RF Link Programming mode or 
re-setting to the initial default condition.  [Show close up picture of Dialer t-board with call-out for 
the push button and jumper switch] 

1.  If the push button is pressed for less than two seconds the Dialer Unit will enter the RF Link 

Programming mode.  The Dialer unit will remain in this mode until programming is complete 
or until the RF Link Programming mode has failed.  

2.  Pushing the button with for 

more than 10 seconds

 will reset the Loop Sensor to the default 

condition. 

 
The Dialer Unit also is equipped with a “jumper switch” which can be used to test the RF Link during 
product installation and set-up. 
 

2.0 Planning the Safe Dog

®

 Monitor Installation 

 
Planning the location of the Safe Dog Monitor components is critical to proper operation and 
providing a professional installation.  Before permanently mounting any components (Loop Sensor or 
Dialer Unit), verify proper operation.  Please read all instructions contained in this manual before 
installing the Safe Dog Monitor.  
 

2.1 Safe Dog Monitor Loop Sensor 

The Loop Sensor should be located on a flat wall surface near the Invisible Fence Brand transmitter.   

Содержание Safe Dog Monitor

Страница 1: ...Rev 1 0 JAB Safe Dog Monitor Installation and Training Manual ...

Страница 2: ...tallation Diagram 3 2 2 Mounting the Safe Dog Monitor Loop Sensor 3 2 3 Routing the Signal Field Wires 3 2 4 Connecting AC Power 3 2 5 Connecting to the Transmitter Battery Back up 3 2 6 Calibrating the Signal Field to the Loop Sensor 3 3 Safe Dog Monitor Dialer Unit 3 3 1 Installation Diagram 3 3 2 Connecting Power 3 3 3 Connecting the Phone Line 3 3 4 Successful RF Communication Link 3 3 5 Mount...

Страница 3: ...EST LAB 2006 Reports TRP Safe Dog Monitor Part 68 TCB Documents KZ3 050808 manual doc Need Part Number 5 1 Registration Process 5 1 1 Pre registration 5 1 2 Registration Before Installation 5 1 3 Registration After Installation ...

Страница 4: ...ings Caution Never install or service any Invisible Fence Brand equipment during a thunderstorm or electrical storm or when thunder or lightning are in your area 1 3 Required System Components for Installation The following system components are required for installation of the Safe Dog Monitor 1 Safe Dog Monitor Loop Sensor Picture of Loop Sensor 2 Safe Dog Monitor Dialer Unit Picture of Dialer U...

Страница 5: ...ready linked to the Dialer Unit and the push button is pressed for less than two seconds the Loop Sensor will calibrate to the signal field These values will be used for determining the presence of a signal reduction increase loss imbalance 3 Pushing the button with for more than 10 seconds will reset the Loop Sensor to the default condition 1 6 Dialer Unit User Control The Dialer Unit has a push ...

Страница 6: ...tor Pay careful attention to the sequence of the steps 3 1 Programming the Safe Dog Monitor Loop Sensor and Dialer Unit RF Link Programming of the Loop Sensor and Dialer Unit is critical to proper operation of the Safe Dog Monitor Without successful programming the Loop Sensor and Dialer Unit cannot communicate with each other The steps outlined in section 3 1 1 must be followed in order to succes...

Страница 7: ...ate and remove it To fasten the Loop Sensor base to the wall you need two inch long 19mm 8 or 10 pan head sheet metal screws Show picture of Loop Sensor base pointing out mounting holes and wire channels with call outs 3 2 3 Routing the Signal Field Wires The next step in the installation process is to route the signal field wires coming from the LP 4100 through the wire channels in the Loop Senso...

Страница 8: ...se the control button on the Loop Sensor Show picture of Loop Sensor circuit board with call out The LED status indicator will be off during the signal field calibration 6 Once calibration is complete the LED status indicator will show a slow flashing green indicating normal operating mode This process should take no longer than fifteen seconds 7 Replace the Loop Sensor cover 3 3 Safe Dog Monitor ...

Страница 9: ...Dog Monitor Dialer Unit To mount the Dialer Unit to the wall first remove the cover of the unit To remove the cover hold the unit in one hand and using your thumb and index finger of your other hand gently compress the side of the cover plate and remove it To fasten the Dialer Unit base to the wall you need two inch long 19mm 8 or 10 pan head sheet metal screws Show picture of Dialer unit base poi...

Страница 10: ...a loop low failure alarm when the signal field on either sensing circuit is reduced by X X of the calibration value The loop low failure notification will consist of a slow flashing Red LED and transmission of an alert to the Dialer Unit 4 2 2 Increase in Signal Field The Loop Sensor shall generate a loop high failure alarm when the signal field on either sensing circuit is increased by 50 150 of ...

Страница 11: ...8 TCB Documents KZ3 050808 manual doc Need Part Number 5 Alert code The above information will only be transmitted to the Dealer and Distributor if the Safe Dog Monitor Registration process is completed Review section 5 0 for instructions on completing the registration process ...

Страница 12: ...D is off System OK Green Slow 1 second on 4 seconds off Not linked to Dialer Unit Yellow Fast alternating on off RF Link Mode Red Green Alternating between red and green RF Link established not calibrated to the signal field Yellow Solid RF Link established no signal field detected Red Solid Fault condition detected Red Slow flash 1 second on 4 seconds off 4 5 2 Safe Dog Monitor Dialer Unit Condit...

Страница 13: ...t level of registration If Invisible Fence Inc receives a notification call from a Dialer Unit that has only been through both this levels an email will be sent to the Distributor and Dealer The email alert notification will only contain the Dialer Unit serial number and the alert condition code Specific customer information will not be included For detailed directions on pre registering the Safe ...

Страница 14: ...be done on the installation contract of installation checklist When the paperwork is returned to the office the information can be entered into the Safe Dog Monitor warranty database This site can be accessed at enter site address A user name and password is required to access this protected site A Safe Dog Monitor section is available to each Invisible Fence Brand Dealer This section allows the D...

Страница 15: ... area An FCC compliant telephone cord and modular plug are provided with this equipment which is designed to connect to the telephone network or premises wiring using a Part 68 compliant compatible jack See installation instructions for details This equipment uses the following USOC jacks RJ11C If trouble is experienced with this equipment for repair or warranty information please contact your Inv...

Отзывы: