INVERTEC optidrive E IP20 Скачать руководство пользователя страница 2

Optidrive ODE-3 1Ph Output User Guide Revision 1.00 

www.invertekdrives.com 

 

 

1

 

Q

u

ick

 Sta

rt

 Up

 

1.

 

Quick Start Up...................................................................................................................................................................... 4

 

1.1.

 

Important Safety Information 

4

 

1.2.

 

Quick Start Process 

5

 

2.

 

General Information and Ratings ......................................................................................................................................... 7

 

2.1.

 

Identifying the Drive by Model Number 

7

 

2.2.

 

Drive Model Numbers 

7

 

3.

 

Mechanical Installation ........................................................................................................................................................ 8

 

3.1.

 

General 

8

 

3.2.

 

UL Compliant Installation 

8

 

3.3.

 

Mechanical Dimensions and Mounting – IP20 Open Units 

8

 

3.4.

 

Guidelines for Enclosure Mounting – IP20 Units 

8

 

3.5.

 

Mechanical Dimensions – IP66 (Nema 4X) Enclosed Units 

9

 

3.6.

 

Guidelines for mounting (IP66 Units) 

9

 

3.7.

 

Gland Plate and Lock Off 

10

 

3.8.

 

Removing the Terminal Cover 

10

 

3.9.

 

Routine Maintenance 

10

 

4.

 

Power Wiring ..................................................................................................................................................................... 11

 

4.1.

 

Grounding the Drive 

11

 

4.2.

 

EMC Filter Disconnect 

11

 

4.3.

 

Wiring Precautions 

11

 

4.4.

 

Incoming Power Connection 

12

 

4.5.

 

Drive and Motor Connection 

12

 

4.6.

 

Motor Thermal overload Protection 

12

 

4.7.

 

Control Terminal Wiring 

12

 

4.8.

 

Connection Diagram 

13

 

4.9.

 

Using the REV/0/FWD Selector Switch (Switched Version Only) 

14

 

4.10.

 

Control Terminal Connections 

14

 

5.

 

Operation .......................................................................................................................................................................... 15

 

5.1.

 

Managing the Keypad 

15

 

5.2.

 

Changing Parameters 

15

 

5.3.

 

Read Only Parameter Access 

15

 

5.4.

 

Resetting Parameters 

15

 

5.5.

 

Resetting A Fault 

15

 

6.

 

Parameters ........................................................................................................................................................................ 16

 

6.1.

 

Standard Parameters 

16

 

6.2.

 

Extended Parameters 

17

 

6.3.

 

P-00 Read Only Status Parameters 

20

 

6.4.

 

Single Phase Motor - Boost Starting cycle

 

21

 

7.

 

Analog and Digital Input Macro Configurations ................................................................................................................. 22

 

7.1.

 

Overview 

22

 

7.2.

 

Macro Functions Guide Key 

22

 

7.3.

 

Macro Functions – Terminal Mode (P-12 = 0) 

22

 

7.4.

 

Macro Functions - Keypad Mode (P-12 = 1 or 2) 

23

 

7.5.

 

Macro Functions - Fieldbus Control Mode (P-12 = 3, 4, 7, 8 or 9) 

23

 

7.6.

 

Macro Functions - User PI Control Mode (P-12 = 5 or 6) 

23

 

7.7.

 

Fire Mode 

24

 

8.

 

Modbus RTU Communications ........................................................................................................................................... 25

 

8.1.

 

Introduction 

25

 

8.2.

 

Modbus RTU Specification 

25

 

8.3.

 

RJ45 Connector Configuration 

25

 

8.4.

 

Modbus Telegram Structure 

25

 

8.5.

 

Modbus Register Map 

25

 

9.

 

Technical Data ................................................................................................................................................................... 26

 

9.1.

 

Environmental 

26

 

9.2.

 

Rating Tables 

26

 

9.3.

 

Additional Information for UL Compliance 

27

 

10.

 

Trouble Shooting ........................................................................................................................................................... 28

 

10.1.

 

Fault Code Messages 

28

 

 

 

Содержание optidrive E IP20

Страница 1: ...h Output User Guide Revision 1 00 www invertekdrives com 1 1 Quick Start Up User Guide Single Phase Output IP20 IP66 NEMA 4X AC Variable Speed Drive 0 37 1 1kW 0 5 1 5HP 110 230V Installation and Oper...

Страница 2: ...ection Diagram 13 4 9 Using the REV 0 FWD Selector Switch Switched Version Only 14 4 10 Control Terminal Connections 14 5 Operation 15 5 1 Managing the Keypad 15 5 2 Changing Parameters 15 5 3 Read On...

Страница 3: ...h EMC standards is dependent on a number of factors including the environment in which the drive is installed motor switching frequency motor cable lengths and installation methods adopted Compliance...

Страница 4: ...t which normally will be limited by the fuses or MCB Suitably rated fuses or MCB should be fitted in the mains supply to the drive according to any local legislation or codes Do not carry out any work...

Страница 5: ...4X Enclosed Units Guidelines for mounting IP66 Units 8 8 8 9 5 Select the correct power and motor cables according to local wiring regulations or code noting the maximum permissible sizes 9 2 Rating T...

Страница 6: ...to Start Open to Stop Connect a potentiometer 5k 10k between terminals as shown to vary the speed from P 2 0Hz default to P 01 50 60 Hz default 0 10V 0 50 60Hz Quick Start IP66 Switched Switch the uni...

Страница 7: ...c Brake Transistor 1 Not Fitted 4 Internal Transistor Frame Size Filter Type 0 No Filter F Internal EMC Filter Input Voltage 1 110 115 2 200 240 No Of Input Phases Output Current x 10 2 2 Drive Model...

Страница 8: ...environments according to IEC 664 1 For pollution degree 2 or higher environments drives should be mounted in a suitable control cabinet with sufficient ingress protection to maintain a pollution deg...

Страница 9: ...t be mounted vertically on a suitable flat surface The minimum mounting clearances as shown in the table below must be observed The mounting site and chosen mountings should be sufficient to support t...

Страница 10: ...conduit installations the conduit entry holes require standard opening to the required sizes specified per the NEC Not intended for installation using rigid conduit system Power Isolator Lock Off On t...

Страница 11: ...der joist a floor ground rod or bus bar Grounding points must comply with national and local industrial safety regulations and or electrical codes Motor Ground The motor ground must be connected to on...

Страница 12: ...mains supply for motors which have been wound for operation with a variable speed drive then there is no preventative measures required however if the quality of insulation is unknown then the motor...

Страница 13: ...ons A Incoming Power Supply B External Isolator Disconnect C External MCB or Fuse D Optional Input Choke E Optional Input Filter F Optional Brake Resistor G Shielded Motor Cable H Analog Digital Outpu...

Страница 14: ...d 1 STOP Run PI Control 5 6 0 Selectable PI control or preset speed Run Pot STOP Run PI Control 5 6 0 Selectable PI control or Pot speed control Enable STOP Enable 7 8 0 Control from CAN interface Run...

Страница 15: ...Read Only Parameter Access 5 4 Resetting Parameters Press and hold the Navigate key 2 seconds Press and hold the Navigate key 2 seconds To reset parameter values to their factory default settings pre...

Страница 16: ...um Speed Preset Speeds etc will also be displayed in RPM Note If P 09 value is changed P 10 value is reset to 0 P 11 Start Boost Voltage 0 0 100 0 3 0 This parameter sets the initial voltage applied t...

Страница 17: ...mit set in P 19 9 Drive Ready to Run Logic 1 when the drive is ready to run no trip present P 19 Relay Threshold Level 0 0 200 0 100 0 Adjustable threshold level used in conjunction with settings 4 to...

Страница 18: ...inal Enable 3 Previous Speed Terminal Enable 4 Current Speed Keypad Start 5 Preset Speed 4 Keypad Start 6 Current Speed Terminal Start 7 Preset Speed 4 Terminal Start P 32 Starting Boost Frequency 0 0...

Страница 19: ...for the PID Reference Setpoint 0 Digital Preset Setpoint P 45 is used 1 Analog Input 1 Setpoint Analog input 1 signal level readable in P00 01 is used for the setpoint P 45 PI Digital Setpoint 0 0 10...

Страница 20: ...process data output outgoing process data TX PDO1 for CANopen PO1 PO2 PO3 PO4 P00 23 Accumulated time with heatsink 85 C Hours Total accumulated hours and minutes of operation above heatsink temp of...

Страница 21: ...Set the Boost Period Duration P 33 to the maximum allowed value of 150 seconds 5 Start the drive and display the motor current press the Navigate button until the display shows x x where x is the mot...

Страница 22: ...reference selected according to other digital input status FAST STOP P 24 When both inputs are active simultaneously the drive stops using Fast Stop Ramp Time P 24 E TRIP External Trip input which mu...

Страница 23: ...9 P 15 DI1 DI2 DI3 AI2 DI4 AI1 Diagram 0 1 0 1 0 1 0 1 0 STOP ENABLE FB REF Fieldbus Speed Reference Modbus RTU CAN Master Slave defined by P 12 1 1 STOP ENABLE PI Speed Reference 5 3 STOP ENABLE FB R...

Страница 24: ...llowing protection features in the drive O t Heat sink Over Temperature U t Drive Under Temperature Th FLt Faulty Thermistor on Heat sink E trip External Trip 4 20 F 4 20mA fault Ph Ib Phase Imbalance...

Страница 25: ...2 Bytes Register Address 2 Bytes Register Address 2 Bytes No Of Registers 2 Bytes 2nd Register Value 2 Bytes Value 2 Bytes Register Value 2 Bytes CRC Checksum 2 Bytes Etc CRC Checksum 2 Bytes CRC Che...

Страница 26: ...er a 24 hour period for 200 240V 2 2kW and 3HP IP20 drives is 45 C 9 2 Rating Tables Frame Size kW HP Input Current Fuse MCB Type B Maximum Cable Size Output Current Recommended Brake Resistance Non U...

Страница 27: ...stated in section 9 1 For IP20 units installation is required in a pollution degree 1 environment For IP66 Nema 4X units installation in a pollution degree 2 environment is permissible Electrical Ins...

Страница 28: ...the drive and that the bottom entry and top exit vents are not blocked or obstructed 09 Under temperature Trip occurs when ambient temperature is less than 10 C Temperature must be raised over 10 C i...

Отзывы: