Table 5 General Specifications 

I NVERTER MODEL 

3.2KVA 

5.2KVA 

SCC type 

MPPT 

Parallel- able 

YES 

Communication 

RS232 + Bluetooth 

Safety Certification 

CE 

Operating Temperature 

Range 

0°C to 55°C 

Storage temperature 

-15°C~ 60°C 

Humidity 

5% to 95% Relative Humidity (Non-condensing) 

Dimension  

( D* W* H) , mm 

525 x 315 x 140 

Net Weight, kg 

13.0 13.5 

 

 

Содержание Axpert King 3.2KW

Страница 1: ...Axpert King 3 2KW 5 2KW 48V MPPT SOLAR I NVERTER Version 1 0 User Manual...

Страница 2: ...on Connection 8 Dry Contact Signal 9 OPERATI ON 10 Power ON OFF 10 Operation and Display Panel 10 LCD Display Icons 10 LCD Setting 13 Display Setting 20 Operating Mode Description 24 Fault Reference C...

Страница 3: ...ff the unit will not reduce this risk 5 CAUTI ON Only qualified personnel can install this device with battery 6 NEVER charge a frozen battery 7 For optimum operation of this solar inverter please fol...

Страница 4: ...on applications via LCD setting Configurable AC Solar Charger priority via LCD setting Compatible to mains voltage or generator power Auto restart while AC is recovering Overload Over temperature sho...

Страница 5: ...ntact 9 Reserved 10 Reserved 11 RS232 communication port 12 RS232 communication indicator 13 Reserved 14 Reserved 15 Dry contact indicator 16 Bluetooth indicator 17 Function buttons 18 Power on off sw...

Страница 6: ...ng points before selecting where to install Do not mount the inverter on flammable construction materials Mount on a solid surface Install this inverter at eye level in order to allow the LCD display...

Страница 7: ...le and terminal size as below Recommended battery cable and terminal size Model Typical Amperage Battery Capacity Wire Size Ring Terminal Torque Value Cable mm2 Dimensions D mm L mm 3 2KVA 200A 200AH...

Страница 8: ...of AC breaker is 30A for 3 2KVA 50A for 5 2KVA CAUTI ON There are two terminal blocks with IN and OUT markings Please do NOT mis connect input and output connectors WARNI NG All wiring must be perfor...

Страница 9: ...recommended cable size as below Model Typical Amperage Cable Size Torque 3 2KVA with MPPT 60A 6 AWG 1 2 1 6 Nm 5 2KVA with MPPT 80A CAUTI ON I mportant Be sure to connect AC wires with correct polari...

Страница 10: ...r positive and negative conductors 2 Check correct polarity of connection cable from PV modules and PV input connectors Then connect positive pole of connection cable to positive pole of PV input conn...

Страница 11: ...red Close Open Power On Output is powered from Utility Close Open Output is powered from Battery or Solar Program 01 set as Utility Battery voltage Low DC warning voltage Open Close Battery voltage Se...

Страница 12: ...status and input output power information LED I ndicator LED I ndicator Messages Left LED I ndicator Green Reserved Reserved Green Reserved Reserved Green Reserved Reserved Right LED I ndicator Green...

Страница 13: ...discharging current Battery I nformation Indicates battery level by 0 24 25 49 50 74 and 75 100 in battery mode and charging status in line mode In AC mode it will present battery charging status Stat...

Страница 14: ...49 50 74 and 75 100 0 24 25 49 50 74 75 100 Mode Operation I nformation Indicates unit connects to the mains Indicates unit connects to the PV panel Indicates load is supplied by utility power Indica...

Страница 15: ...r energy is not sufficient to power all connected loads utility energy will supply power to the loads at the same time Battery provides power to the loads only when solar and utility is not sufficient...

Страница 16: ...ault Restart enable 07 Auto restart when over temperature occurs Restart disable default Restart enable 09 Output frequency 50Hz default 60Hz 10 Operation Logic Automatically default If selected and u...

Страница 17: ...ity in program 01 3 2KVA default setting 23 0V 5 2KVA default setting 46 0V 3 2KVA model setting range is from 22 0V to 28 5V and increment of each click is 0 5V 5 2KVA model setting range is from 44...

Страница 18: ...llow AC charge battery Solar power load first and allow AC charge battery Solar power load first and disallow AC charge battery 18 Alarm control Alarm on default Alarm off 19 Auto return to default di...

Страница 19: ...ss mode if utility is available 25 Record Fault code Record enable Record disable default 26 Bulk charging voltage C V voltage 3 2KVA default setting 28 2V 5 2KVA default setting 56 4V If self defined...

Страница 20: ...click is 5min Otherwise Keeping auto charging time 33 Battery equalization Battery equalization Battery equalization disable default If Flooded or User Defined is selected in program 05 this program c...

Страница 21: ...on until next activated equalization time arrives based on program 35 setting At this time will not be shown in LCD main page 40 Reset PV and Load energy storage Not reset Default Reset 95 Time settin...

Страница 22: ...rent charging power battery voltage output voltage output frequency load percentage load in Watt load in VA load in Watt DC discharging current main CPU Version Selectable information LCD display Inpu...

Страница 23: ...charging current 50A AC charging current 50A Charging power AC and PV charging power 500W PV charging power 500W AC charging power 500W Battery voltage and output voltage Battery voltage 25 5V output...

Страница 24: ...ent x xkVA like below chart Load in Watt When load is lower than 1kW load in W will present xxxW like below chart When load is larger than 1kW 1KW load in W will present x xkW like below chart Battery...

Страница 25: ...utput energy this year This PV year energy 3 88MWh Load year energy 9 88MWh PV energy generated totally and Load output total energy PV Total energy 38 8MWh Load Output Total energy 98 8MWh Real date...

Страница 26: ...on yet but at this time the inverter can charge battery without AC output No output is supplied by the unit but it still can charge batteries Charging by utility and PV energy Charging by utility Char...

Страница 27: ...Charging by utility and PV energy Charging by PV Charging by utility No charging Line Mode The unit will provide output power from the mains It will also charge the battery at line mode Charging by ut...

Страница 28: ...02 Over temperature 03 Battery voltage is too high 04 Battery voltage is too low 05 Output short circuited or over temperature is detected by internal converter components 06 Output voltage is too hig...

Страница 29: ...second 02 Over temperature None 03 Battery is over charged Beep once every second 04 Low battery Beep once every second 07 Overload Beep once every 0 5 second 10 Output power derating Beep twice ever...

Страница 30: ...g LCD setting program 33 first Then you may apply this function in device by either one of following methods 1 Setting equalization interval in program 37 2 Active equalization immediately in program...

Страница 31: ...n voltage point the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage If battery voltage is still lower than battery equalization vol...

Страница 32: ...Nominal I nput Frequency 50Hz 60Hz Auto detection Low Loss Frequency 46 56 1Hz Low Loss Return Frequency 46 5 57 1Hz High Loss Frequency 54 64 1Hz High Loss Return Frequency 53 63 1Hz Power Factor 0 9...

Страница 33: ...2 rated power for 5 seconds Nominal DC I nput Voltage 24Vdc 48Vdc Operating Range 20Vdc 34Vdc 40Vdc 66Vdc Cold Start Voltage 23Vdc 46Vdc Low DC Warning Voltage 22 5Vdc 22 0Vdc 45 0Vdc 44 0Vdc load 50...

Страница 34: ...rge Protection 34Vdc 66Vdc Charging Algorithm 3 Step Charging Curve Solar Charging Mode MPPT type I NVERTER MODEL 3 2KVA 5 2KVA Rated Power 1500W 4000W Maximum charging current 60A 80A Efficiency 98 0...

Страница 35: ...ty or generator Low Loss Voltage 176Vac 7V Low Loss Return Voltage 186Vac 7V High Loss Voltage 280Vac 7V High Loss Return Voltage 270Vac 7V Nominal I nput Frequency 50Hz 60Hz Auto detection Low Loss F...

Страница 36: ...SCC type MPPT Parallel able YES Communication RS232 Bluetooth Safety Certification CE Operating Temperature Range 0 C to 55 C Storage temperature 15 C 60 C Humidity 5 to 95 Relative Humidity Non conde...

Страница 37: ...repeatedly LCD display and LEDs are flashing Battery is disconnected Check if battery wires are connected well Buzzer beeps continuously and red LED is on Fault code 07 Overload error The inverter is...

Страница 38: ...5 94 2700 31 74 3000 28 67 3200 24 60 Model Load VA Backup Time 48Vdc 200Ah min Backup Time 48Vdc 400Ah min 5 2KVA 500 613 1288 1000 268 613 1500 158 402 2000 111 271 2500 90 215 3000 76 182 3500 65 1...

Отзывы: