17
20 Backlight
control
Backlight on (default)
Backlight off
22
Beeps while primary source
is interrupted
Alarm on (default)
Alarm off
23 Bypass
function:
Bypass Forbidden
If selected, inverter won’t work
in bypass/ECO state.
Bypass disable
If selected, and power ON
button is pressed on, inverter
can work in bypass/ECO state if
utility is available.
Bypass enable (default)
If selected and no matter power
ON button is pressed on or not,
inverter can work in bypass
mode if utility is available.
25 Record
Fault
code
Record enable
Record disable (default)
26
Bulk charging voltage
(C.V voltage)
3.2
KVA default setting: 28.2V
5.2
KVA default setting: 56.4V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 24.0V to 32.0V for 3.2KVA model and
48.0V to 64.0V for 5.2KVA model. Increment of each click is 0.1V.
27
Floating charging voltage
3.2
KVA default setting: 27.0V
5.2
KVA default setting: 54.0V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 24.0V to 32.0V for 3.2KVA model and
48.0V to 64.0V for 5.2KVA model. Increment of each click is 0.1V.