51
10. Appendices
10.1. Change log
Current version
-
v5.08
----------------------------------------------------------------
V5.08.01
- SPI transmission has been slowed down for Q24PLUS (too fast
transmission could led to unwanted GPRS retries)
V5.08.00
- ATTENTION!!! Version 5.08 and higher work only with modem
firmware version 657e09gg
added GPRS testing function
added choice between sending IP or S/N in "MT" frame header
V4.07.00
- added four band modem Q24PLUS support. Needs updating modem
firmware to version 657d09gg.Q24PL001
V2.00.01
- ATTENTION!!! Version 2.00 and higher work only with modem
firmware version 651a09gg - change was dictated by hardware
changes in Q2406B modem (new FLASH memory).
V1.06.02
-
actualization of memory map
v1.06
- first
released
version
10.2. Triggering inputs
During operation, the internal system of
MT-703
module creates a number of variables
related to its inputs/outputs and to module diagnostics. Triggering inputs and triggering
flags
in conjunction with rules processing enable instantaneous reaction in occurring
states.
User has access to following triggering inputs:
Input Description
I1...I3 binary
inputs
A1, A2
analogue inputs A1, A2
Bat_Low
'1'
if voltage level of modules power source falls below
limit value set by
Low battery voltage alarm level
parameter
Pow_On
'1' when module is powered on
T1,T2
T1,T2 timers flags