30
inVENTer
®
iV12-Smart
®
/iV12-Smart
®
Corner ventilation system
•
Installation and operating instructions
►
Afix sealing tape 9 mm (6) around the outer edge
of the weather protection hood base plate (7).
►
Ensure that the sealing tape (6) is at a
distance of 5 mm from the outer edge of the
weather protection hood base plate (7).
►
Ensure that the sealing tape (6) is affixed
on the external wall side to the weather
protection hood base plate (7).
6
7
5
►
Fit weather protection hood base plate (9) above
wall sleeve and mount on external wall.
►
Pay attention to the position of the drip rail at
the top / bottom.
►
Align weather protection hood base plate (9)
using a spirit level (8).
►
Mark out four holes (10).
►
Drill holes (10) with Ø 8 mm to a depth of min.
50 mm and insert wall plugs.
8
9
0
1
►
Secure weather protection hood base plate (11)
to the external wall using screws (12).
1
1
2
1
►
Insert screws (13) at the top on the sides of the
weather protection hood cover (16).
►
Hook weather protection hood cover (16) via
slots (14) on to top side screws (13) of the
weather protection hood base plate.
►
Secure weather protection hood cover (16) to
weather protection hood base plate using top and
bottom screws (13, 15).
13
13
15
14
Ö
Ö
The weather protection hood WSH-Smart is itted.