Страница 2: ...sult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enoug...

Страница 3: ... A W G Up to 50 ft 14 50 100 ft 12 Before assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with thi...

Страница 4: ...rical shock WARNING WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 1 Remove...

Страница 5: ...e 6 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Turn fan motor assembly upside down in preparation for mounting fan blades Position the top and bottom halves of the styrofoam packaging on end with solid...

Страница 6: ...ted correctly color to color before they can be engaged Make sure the connector latch closes properly NOTE Make sure all wires and connector are tucked under the light kit assembly and not pinched between light kit assembly and lower housing 12 Remove one 8 32 x 10mm pan head screw from the lower housing reserve for later use Loosen the other two screws to assemble the light kit assembly to the lo...

Страница 7: ... Y WIRES AND FAN WIRES OMITTED FOR CLARITY OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY 1 1 4 THREADED STUD 2 Figure 13 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet ...

Страница 8: ...act a licensed electrician for advice as it must be grounded for safe operation NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Check to see that all connections are tight including ground and that no bare wire is visible at the wir...

Страница 9: ...pple Figure 17 NOTE Periodically check that the glass bowl is seated correctly in the light kit assembly and the hex jamnut and finial nut are tightly fastened 5 Assembly of the ceiling fan is now complete Restore electrical power to the branch circuit at the fuse box or breaker panel 6 Slide the small wood penadant onto the center fan speed chain secure by connecting the coupling to the chain Sli...

Страница 10: ...an could result in fire shock and personal injury 1 Ceiling Fan Light Controls see store or catalog WARNING WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be ...

Страница 11: ... inside switch housing 3 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to flywheel 4 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively ...

Страница 12: ...12 Repair Parts 17 9 8 1 7 3 2 5 26 19 20 6 18 21 22 11 11 24 15 14 13 12 25 10 23 4 16 U L Model No CF850 ...

Страница 13: ...upling Cover 1 764100 AW 764100 GES 764100 VNB 19 Wiring Harness 1 764171 AW 764171 GES 764171 VNB 20 Lower Housing Assembly 1 764176 AW 764176 GES 764176 VNB 21 Light Kit Assembly Includes Switch Harness Assembly 1 764178 AW 764178 GES 764178 VNB 22 Light Kit Glass 764180 AW 764180 GES 764180 VNB 23 Bowl Cap 1 764181 AW 764181 GES 764181 VNB 24 Finial Nut 1 764182 AW 764182 GES 764182 VNB 25 Blad...

Страница 14: ...14 U L Model No CF850 Notes ...

Страница 15: ...15 U L Model No CF850 Notes ...

Страница 16: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Отзывы: