27
INSTALLATION AND ASSEMBLY
27
iV-Smart+ ventilation device | Installation instructions
NOTICE: Damage to masonry/exterior wall
due to incorrectly aligned drip edges!
• Make sure that the slopes of both drip
edges are directed towards the floor.
►
Slide the base plate onto the projecting wall sleeve.
Alignment of the drip edges: the slope
leads to the ground.
►
Level the weather protection hood base plate using
a spirit level.
►
Mark the four drill holes.
►
Drill the four holes with Ø 8 mm, min. 50 mm deep.
TIP:
Do not apply the sealing tape until
immediately before installing the base plate.
This prevents the sealing tape from swelling
too much and makes installation easier.
►
From the exterior wall side, attach the 9-mm seal-
ing tape circumferentially flush with the base plate:
• flush with the opening for the wall sleeve
• with 5 mm clearance along the outer edge.
The sealing tape must not protrude at the
inner edge of the wall sleeve opening.
►
Insert the rawl plugs into the boreholes.
►
Screw the weather protection hood base plate into
the rawl plugs using 4 screws and washers.
TIP:
When attaching the base plate to
exterior walls with insulation or when using the
wall installation block/Simplex wall installation
system, use wallplugs for insulation for fixing
purposes. These are not included in the scope
of supply, they are available as an option.
ø 8 mm
5 mm
!
4 x
!
4 x
i
i