13
SYSTEM OVERVIEW: IV-SMART+ VENTILATION DEVICE
13
iV-Smart+ ventilation device | Installation instructions
Multi-zone control
Designation
MZ-Home
inVENTer Connect
Number of controll-
able ventilation devices
Max. 16
(excl. sensors)
Max. 16
(incl. sensors)
Multi-zone control
max. 4 zones with max. 4 devices
[plus sensors] per zone
max. 4 zones; any
number of devices per zone
Operating concept
•
Touch
•
Weekly timer
•
Touch
•
Ventilation profiles
(time controlled)
•
App control
Operating modes
•
Heat recovery
•
Through-ventilation
•
OFF
•
Heat recovery
•
Through-ventilation
•
OFF
Functions
•
Pause function (1 ... 8h)
per zone
•
Dehumidification with variable
air volume flow
•
Dehumidification with variable
air volume flow and other
demand ventilation
•
Pause function
(global and zonal)
•
Boost function
(global and zonal)
•
Basement ventilation
•
Summertime ventilation
Fan speed
4 Output levels,
freely selectable
4 Output levels,
freely selectable
Unit communication
•
Cable
•
868 MHz wireless network
•
Cable
External interface
1 potential-free switching contact
per Clust-Air module (max. 4)
•
Pressure switch (NC/NO)
•
Other sensors (NO)
Several different sensors per
controller platform
(zone division
and number of sensors per zone
arbitrary)
For detailed information, see the controller's installation and operating instructions.
Operating Unit & Clust-Air module
Easy Connect e16
ON
1 2