The corresponding connection diagrams and assembly steps for installing the controller are not
part of this documentation! They can be found in the installation instructions for the respective
control device.
22
INSTALLATION AND ASSEMBLY
22
iV-Smart+ ventilation device | Installation instructions
Principle sketches for cable laying
inVENTer Connect controller platform
Pure, sMove and MZ-Home controllers
System communication by radio:
Cable NYM-J, wire cross-section 1.5 mm²
Ventilation device 1
Control device:
Connect inner cover
House distributor
Ventilation device n
Control device:
Connect inner cover
Operating device:
Easy Connect e16
System communication by cable:
RS485 data cable,
Cross-section 0.25 - 0.5 mm²,
Length max. 500 m
Cable NYM-J, wire cross-section 1.5 mm²
Ventilation device n
Control device:
Connect inner cover
Ventilation device 1
Control device:
Connect inner cover
House distributor
Operating device:
Easy Connect e16
230 V AC
One after the other:
Star-shaped:
Cable type LiYY, 3-wire, wire cross-section 0.75 mm
2
,
length see
controller
Cable type LiYY, 3-wire,
wire cross-section 0.75 mm²,
length max. 33 m
Switching power
supply device
Control device:
Pure: Control module
sMove: Control device
MZ-Home: Clust-Air module
Terminal
blocks
Ventilation devices
Ventilation
devices
Operated in pairs
Operated in pairs
Operated in pairs
Operated in pairs
Control device:
Pure: Control module
sMove: Control device
MZ-Home: Clust-Air module
Switching power
supply device
6 – 16 V DC
230 V AC
6 – 16 V DC