USER AND SAFETY INSTRUCTIONS

4

Aviant extractor fan | Operating instructions

1.1  User information 

Safety and warning instructions

The safety and warning instructions in these installation in-

structions have a uniform structure and are marked with a 

symbol on the left side of the instruction. A signal word in 

front of the text also indicates the hazard level. If several 

hazard levels exist, the highest level safety instruction is 

always used. The safety and warning instructions contain 

the following information: 

SIGNAL WORD

Type and origin of the hazard. 

Possible consequences of the danger!

•  Measures to avoid hazard.

The signal word indicates the severity of the potential 

hazard unless the preventive measures are taken:

DANGER

 means: Imminent danger of serious 

injury or death.

WARNING 

means: Possible danger of serious 

injury or death.

CAUTION

 means: Direct danger or minor/signifi

-

cant injury.

NOTICE

 means: Direct or possible risk of property 

damage due to an adverse event/state.

Other symbols used in this documentation

TIP 

symbol indicates practical and useful tips for 

handling your extractor fan.

► 

Action required: 

This prompts the user to  

 

perform a specific action.

 

Check results: 

Requires user to check results of 

 

the action performed.

All graphics represent the interior wall.

1.2  Safety instructions

The operating instructions are part of your Aviant 

ventilation unit and must be available at all times 

(see www.inventer.eu/downloads). When handing the 

system to a third party, the information regarding access to 

the operating instructions must be handed over also.  

Before carrying out any work on the system, read this 

documentation carefully and observe all the instructions for 

operation and maintenance given in this chapter. Also note 

the safety instructions that precede the described handling 

instructions. 

Non-observance of safety instructions could result in injury 

and/or property damage.

User and Safety instructions

Thank you for purchasing this high quality product from inVENTer!  

This section provides an overview of the basic safety precautions for safe and proper operation of your 

ventilation system.

i

Содержание Aviant

Страница 1: ...Operating instructions Aviant Extractor fan www inventer eu ...

Страница 2: ... be given for complete conformity This documentation describes the functionality of the standard scope For reasons of clarity the documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario of operation cleaning and maintenance The illustrations in this document may differ slightly from the design of the product that you have purchase...

Страница 3: ...ontrol panel 8 4 1 Humidity sensor 9 4 2 Light and Air quality sensor 10 4 3 Run on and Switch on delay 10 4 4 Permanent operation 12 4 5 Factory settings reset 12 4 App inVENTer Mobile 13 4 1 Add Aviant to the app 13 4 2 Pair Aviant with the app 14 4 3 The Start menu of the App 15 4 4 Settings menus der App 15 5 Cleaning and care 16 6 Accesories and spare parts 18 7 Warranty and guarantee 18 8 Se...

Страница 4: ...adverse event state Other symbols used in this documentation A TIP symbol indicates practical and useful tips for handling your extractor fan Action required This prompts the user to perform a specific action Check results Requires user to check results of the action performed All graphics represent the interior wall 1 2 Safety instructions The operating instructions are part of your Aviant ventil...

Страница 5: ...e operated and cleaned by children and or persons who due to their physical sensory or mental capabilities inexperi ence or lack of knowledge are not safely able to do so unless they are supervised by a person responsible for their safety or have been instructed by him her on how to operate the ventilation unit Small children must be supervised so that they do not play with the device NOTICE The d...

Страница 6: ...air flow volume can be adjusted via the app or on the control panel Air quality sensor Increase of the air flow volume when the air quality in the interior deteriorates The intensity corresponds to the selected maximum when activating the humidity sensor Run on Function After the switch off pulse humidity sensor light sensor or external switching contact as pulse generator the fan continues to run...

Страница 7: ...vice is set in continuous operation permanent ventilation Note The sensors are switched with priority If the Aviant was ac tivated in the meantime by means of sensors the basic ventilation cycle is shifted back accordingly The intensity of the air flow volume can be set via the app or on the control panel The following factory settings are active when the fan is first started up Automatic Basic Ve...

Страница 8: ...ght Connection error Touch the Function icon or start the inVENTer mobile application again Quick overview To access the control panel first remove the Aviant s magnetic inner cover To access the programmable functions press the following icon All programmable function icons light up Run on timer Switch on delay Humidity sensor Continuous ventilation Light and Air quality sensor To activate the de...

Страница 9: ...Set the air flow volume when activated by the humidity sensor and the air quality sensor In this menu item the air flow volume is set when the Aviant is activated by the humidity sensor as well as the air quality sensor Touch the icon to activate the control panel Touch the icon Ö The indicator light becomes active Touch the symbol twice to apply the changes Ö The air flow volume when activated by...

Страница 10: ... If no run on time is set the fan switches off immediately Touch the icon to activate the control panel Touch the icon Ö The currently set run on time is displayed 15 minutes 30 minutes 3 3 Run on time and switch on delay 3 2 Light and Air quality sensor The light sensor is used to automatically monitor changes in light The air quality sensor monitors indoor air quality to quickly remove unpleasan...

Страница 11: ...ed by the light sensor Set air flow volume in run on function and when activated by the light sensor In this menu item the air flow volume is set during the run on time and when the Aviant is activated by the light sensor Touch the icon to activate the control panel Touch the icon Ö The indicator light becomes active Touch the symbol twice to apply the changes Ö The air flow volume during the run ...

Страница 12: ...d separately exclusively through the app goes out Ö Permanent mode is deactivated OR Touch the icon to increase decrease the air flow volume in permanent mode Set the air flow volume in permanent operation Touch the icon to activate the control panel Touch the icon Ö The indicator light becomes active Touch the symbol twice to apply the changes Ö The air flow volume in permanent operation is set 3...

Страница 13: ... Android or App Store iOs 4 1 Add Aviant to the app Download the inVENTer Mobile app to your mobile device mobile phone or tablet with Android or iOS operating system Ö After successful installation of the app the corresponding icon appears on the display screen To connect the app to the Aviant Bluetooth must be enabled and the app must be granted location sharing Enable Bluetooth and location on ...

Страница 14: ...or Ö Your Aviant and the mobile device connect Ö The symbol on the control panel lights up permanently Intensität Nachlauffunktion Einschaltverzögerung Funktionsanzeige Feuchtesensor Permanentbetrieb Licht und Luftqualitätssensor 8 sec i If you have already installed the inVENTer Mobile App on your mobile device and have already connected devices you can add your Aviant to the device list by selec...

Страница 15: ... menu of the selected function opens Display currently set function parameter Adjustment range air flow volume Setting range of other parameters varies depending on the selected function menu Enable disable the function Sensor sensitivity Set run on time switch on delay pause times boost times The following functions can be set exclusively via app Boost function maximum air flow volume for a defin...

Страница 16: ...The necessary cleaning and maintenance work can be carried out by the user after a short instruction The measures and intervals listed here are recommendations by inVENTer GmbH to maintain the func tional and performance capability of your Aviant Cleaning agents The Aviant extractor fan has a plastic surface that is sen sitive to scratches Do not use cleaning agents containing sand soda acid or ch...

Страница 17: ...CLEANING AND CARE 17 Aviant extractor fan Operating instructions Off On 1 2 3 4 5 6 7 8 ...

Страница 18: ...tory representative responsible for you In any case send the complete unit back to the manufacturer The warranty claim is an additional offer by the manufactur er and does not affect applicable law in any way 8 Service Complaints Check the delivery for completeness and transport damage upon receipt using the delivery note Complain about miss ing items immediately at the latest within 14 days to yo...

Страница 19: ...ACCESORIES AND SPARE PARTS 19 Aviant extractor fan Operating instructions NOTES ...

Страница 20: ...Item Number 5010 0015 Version 1 0 05 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstraße 4a D 07751 Löberschütz Germany www inventer eu ...

Отзывы: