User’s Manual
XC-RF850 Reader
37
Trigger condition: Available options shown below:
Close (turn off trigger condition)
Falling edge (level changes from high to low)
Rising edge trigger (level changes from low to high)
High level trigger (high steady state)
Low level trigger (low steady state)
Termination condition: Available in delay timing and port level.
Delay timing: Configure the continuous operating duration and cause the reader
to stop automatically once time runs up. Unit: 0.1 second.
Port level: Automatically select condition that contradicts the trigger condition.
Detailed explanation: I/O trigger is an automated tag reading function that is
based on I/O trigger condition and transfers the tag data to the host PC. There
are two trigger ports that can be configured independently. The tag reading
configuration is similar to the current reader scanning configuration.
Note: When configuring tag reading trigger, first configure the scanning
configuration. Click on the scanning configuration, same as the setting in 3.4.5,
then configure the trigger port, trigger condition and termination condition.
3 DEMO user guide