T-3™ and T-4™ Series
44
Part No. 1054916
FIGURE 14 - ADJUSTING WHEELBASE WIDTH
A-4 CAMBER TUBE
CAMBER TUBE 2000
Axle Bolt
Axle Nut
NOTE: Axle bolt removed from axle tube for clarity.
It is not necessary to remove the axle bolt for this
procedure.
Threads
Indexing Marks
Axle Tube
Camber Insert
Indexing Ring
Frame Bracket
ADJUSTING WHEELBASE WIDTH (FIGURE 14)
ADJUSTING WHEELBASE WIDTH - A-4 CAMBER TUBE
NOTE: Perform this procedure one (1) side of the wheelchair at a time for ease of adjustment.
1. Open the camber clamps. Refer to OPENING/CLOSING CLAMPS in this procedure of the
manual.
WARNING
NEVER position the camber inserts in the axle tube with more than 3-inches
(12 indexing marks showing) of the camber insert outside of the axle tube. The
camber inserts will not be securely tightened in the axle tube resulting in
possible injury to the user or damage to the wheelchair.
2. Position the camber insert to the desired position. Make sure there is no more than 3-inches
(12 indexing marks showing) of the camber inserts outside of the axle tube.
3. Slide the indexing ring on the camber insert until it is flush with the frame bracket.
NOTE: Before using the wheelchair, make sure both camber inserts are set at the same indexing mark.
This will make sure the distance between the rear wheel and the wheelchair is the same on both sides.
WARNING
QUICK RELEASE LEVERS - Make sure the quick release levers are pointing
towards the rear of the wheelchair and is in the CLOSED position BEFORE
using the wheelchair, otherwise personal injury or damage to the wheelchair
may result.
STANDARD - Make sure the hex screws and locknuts are securely tightened
BEFORE using the wheelchair, otherwise personal injury or damage to the
wheelchair may result.
4. Close the camber clamps. Refer to OPENING/CLOSING CLAMPS in this procedure of the
manual.
5. Repeat STEPS 1-4
for the opposite side of the wheelchair.
WHEELS
PROCEDURE 6
WHEELS
WHEELS