SECTION 10—SAFETY INSPECTION/TROUBLESHOOTING
32
Part No 1125031
4
E04
Right Motor Fault
00
Right Motor Short Circuit
Check the right motor, connections and
motor cable.
01
Right Motor Open Circuit
02 Right Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Right Motor Voltage Fault
05
Right Motor Bridge Fault
06 Too Many Hardware Current
Limit Events
07
Current Offset Out of Range
08 Hardware Current Limit Fault
5
E05
Left Park Brake
Fault
00
Left Park Brake Drive-Time
Test Failed
Check the left park brake connections and
cable.
01
Left Park Brake Output
Enabled When Wheelchair
Idle
02
Left Park Brake Output Did
not Enable When Entering
Drive Mode
03
Left Park Brake fault during
power-up testing
04
Left park brake feedback low
during drive (park brake
short)
6
E06
Right Park Brake
Fault
00
Right Park Brake Drive-Time
Test Failed
Check the right park brake connections
and cable.
01
Right Park Brake Output
Enabled When Wheelchair
Idle
02
Right Park Brake Output Did
not Enable When Entering
Drive Mode
03
Right Park Brake fault during
power-up testing
04
Right park brake feedback
low during drive (park brake
short)
NUMBER OF FLASHES
DIAGNOSTICS CODE
ERROR CODE DESCRIPTION
SUB CO
DE*
DET
A
ILS
OF
ERROR CODE
POSSIBLE SOLUTION