Invacare® Comet Series
Flash code
Fault
Consequence for the
scooter
Comments
6
No neutral position when
switching scooter on.
Stops driving
•
Drive lever is not in neutral when the keyswitch was turned.
Put the drive lever in neutral, turn the power off and then
turn on again.
•
It may be necessary to replace the drive lever. Contact your
Invacare provider.
7
Fault in speed potentiometer
Stops driving
•
The drive lever controls could be faulty or incorrectly
connected. Check the cabling for open or short-circuited
circuitry.
•
Potentiometer is not correctly adjusted and must be replaced.
Contact your Invacare provider.
8
Motor voltage error
Stops driving
•
The motor or its cabling is defective. Check the cabling for
open or short-circuited circuitry.
9
Miscellaneous internal fault
Stops driving
•
Contact your Invacare provider.
10
Push/freewheel mode error
Stops moving
•
The scooter has exceeded the permissible maximum speed
during pushing or freewheeling. Switch the electronics system
off and on again.
54
1603455-A
Содержание Comet Series ALPINE Plus