11.1.2
Error codes and diagnostic codes
Flash code
Fault
Consequence for the
scooter
Comments
1
Batteries must be charged
Continues to drive
•
The batteries are discharged. Charge the batteries as soon
as possible.
2
Battery voltage too low
Stops driving
•
The batteries are depleted. Charge batteries.
•
If you switch the scooter off for a few minutes, the batteries
can often recuperate to such a stage that a short journey is still
possible. You should only do this in an emergency, however,
because this causes the batteries to become excessively
discharged.
3
Battery voltage too high
Stops driving
•
The battery voltage is too high. If the battery charger is
connected, disconnect it from the scooter.
•
The electronic system charges the batteries when running
downhill and when braking. This fault is caused when the
battery voltage becomes too high during this process. Switch
the scooter off and on again.
4
Power time exceeded
Stops driving
•
The maximum current was exceeded over too long a period,
probably because the motor was overloaded or has been
working against an immovable resistance. Switch the scooter
off, wait a few minutes and then switch on again.
•
The electronic system has determined a motor short-circuit.
Check the wiring harness for short-circuit and check the
motor.
•
Contact your Invacare provider.
5
Brake failure
Stops driving
•
Ensure that the disengaging lever is in the engaged position.
•
There is a defect in the braking coil or in the cabling. Check
the magnetic brake and cabling for open or short-circuited
circuitry. Contact your Invacare provider.