background image

Usage

4 Usage

4.1 Before Use

We do not recommend that the product is issued to
anyone without first carrying out a full assessment of their
specific needs. To ensure user safety and contribute to the
best rehabilitation, it is important that the user is given
the necessary support by the product as prescribed by a
qualified professional.

Before use; make sure that all the knobs and screws
are properly tightened on:

width adjustment frame

armrests

handles

4.2 Brakes

1.

A

To lock brake, press down outer edge of brake pedal

A

.

Press outer edge until a click is heard, this
indicates that the wheel is locked.

2.

A

To unlock brake, press inner edge of brake pedal

A

.

4.3 Rear Brakes with Integrated
Directional Lock

only models 1585401, 1587608, 1587609

Directional Lock

A directional lock is used to lock the wheel in a
straight position in order to ease movement straight
ahead.

A

1.

Press down brake pedal

A

one step in order to activate

directional lock.

2.

To unlock directional lock, press inner edge of brake
pedal.

Brake Function

A

1.

Press down brake pedal

A

two steps in order to lock

brake.

2.

To unlock brake, press inner edge of brake pedal.

4.4 Control unit - Step Up Electric

IMPORTANT!

– Allow the battery to charge for 24 hours before

using the height adjustment for the first time.

– Height adjustment is not possible while charging

the battery.

– Ensure that the emergency stop is not pushed

in when the battery is to be charged.

– The product is connected to the mains with a

mains plug. Make sure that the mains plug is
accessible and can be unplugged if required.

B

C

F

G

A

D

E

A

Control Unit

B

Yellow light — ON — Battery charging

B

Yellow light — OFF — Battery fully charged

C

Green light — ON — Motor is in use

1532567-G

7

Содержание 1521677

Страница 1: ...40 1585401 1587608 1587609 en Walking table User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and saved for future reference 1521677 1...

Страница 2: ...whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unles...

Страница 3: ...3 Height adjustment Step Up Electric 10 4 9 Rising to a standing position 10 5 Accessories 11 5 1 Accessories General 11 5 2 Hand Brakes 11 5 2 1 Adjusting the brakes 11 5 3 Hand Brakes for Models wit...

Страница 4: ...inor or slight injury if it is not avoided IMPORTANT Indicates a hazardous situation that could result in damage to property if it is not avoided Tips and Recommendations Gives useful tips recommendat...

Страница 5: ...ating the walking table in the presence of children and pets Take care when moving over obstacles e g doorways when using the walking table with the accessory standing plate The wheels must be locked...

Страница 6: ...on all four wheels models 1521679 and 1579540 Foot operated brake on the front wheels and hand operated brake on the rear wheels model 1536122 Foot operated brake on the front wheels and hand operated...

Страница 7: ...onal Lock A directional lock is used to lock the wheel in a straight position in order to ease movement straight ahead A 1 Press down brake pedal A one step in order to activate directional lock 2 To...

Страница 8: ...angle of 25 between shoulder and wrist position gives the best conditions to enable the torso to remain upright The position is pre set and is maintained regardless of width setting 25 Set the armres...

Страница 9: ...s through the most narrow passage in the premises A B 1 Lay the walking table down 2 Remove screws A 3 Adjust the frame B to the required width on one side 4 Reinsert the screws and tighten with a min...

Страница 10: ...y distributed weight affects the product s stability 125 mm 215 mm Step Up Electric and Step Up Hydraulic can support the user when rising to a standing position The help of an attendant is recommende...

Страница 11: ...ke handle handles A slowly towards handles The more you press the higher the braking force is Engaging Parking Brake The parking brake sets the brake into a locked parking position 1 A To engage parki...

Страница 12: ...owly towards handles The more you press the higher the braking force is Engaging Parking Brake The parking brake sets the brake into a locked parking position 1 A B Press brake handle handles A toward...

Страница 13: ...bottom of the oxygen cylinder must be at least 8 cm from the ground 5 8 IV pole A The IV pole can be mounted on the pillar A and makes it possible to attach a drip bag on the product The Oxygen tank h...

Страница 14: ...tand Assist A B The Stand Assist accessory is available for users who need support while standing and consists of a standing plate A knee support B and a harness With the Stand Assist accessory the wa...

Страница 15: ...e in the cleaning instructions Never use a solvent cellulose thinner acetone etc that changes the structure of the plastic or dissolves the attached labels Always make sure that the product is complet...

Страница 16: ...rding to legislation DO NOT dispose of batteries in normal household waste Batteries MUST be taken to a proper disposal site The return is required by law and free of charge Do only dispose discharged...

Страница 17: ...mm with standard wheel 190 mm with optional 100 mm wheel Maximum user weight 150 kg Maximum load in basket and tray 5 kg Maximum load on the oxygen tank holder 11 kg Maximum load on the IV pole 4 kg P...

Страница 18: ...d to the mains Make sure the walking table is dry before connection it to the mains Operation Storage Transportation Temperature 5 C to 40 C 10 C to 50 C 10 C to 50 C Relative humidity 20 to 100 20 to...

Страница 19: ...ied below The user of the product should assure that it is used in such an environment Immunity test IEC 60601 1 2 test level Compliance level Electromagnetic environment guidance Electrostatic discha...

Страница 20: ...strength in the location in which this product is used exceeds the applicable RF compliance level above the product should be observed to verify normal operation If abnormal performance is observed a...

Страница 21: ...MHz the separation distance for the higher frequency range applies These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures...

Страница 22: ...Notes...

Страница 23: ...Notes...

Страница 24: ...353 1 810 7085 ireland invacare com www invacare ie United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com www in...

Отзывы: