5. GENERATOR EXHAUST SYSTEM
The exhaust system includes a water lift muffler located in the Generator Compartment.
The inlet of the muffler is plumbed directly to the Generator engine exhaust manifold. The outlet
of the muffler is plumbed directly to the Generator Exhaust Thru-hull located on the transom
under the starboard swim platform.
The exhaust system has been plumbed to prevent water from entering the exhaust system of the
Generator engine.
EXHAUST OUT TO
THRU HULL
FITTING
EXHAUST IN
FROM
MANIFOLD TO
MUFFLER
5. GENERATOR CONTROLS
The control box mounted on the Generator includes a switch for starting and stopping the
Generator. Do not use this switch unless the Generator Compartment Blower has been operating
for at least 4 minutes.
NOTE
Refer to the information in the Generator Manufacturer’s Manual for the information on operating
and maintaining your Generator. This manual is included in your Owner’s Pack.
NOTE
To ensure the safety of your boat and those aboard always operate the Generator blower before
operating the Generator. Gasoline vapors collect in the lower bilge and will explode on the event
of an electrical spark in the Generator Compartment.
A remote Start/Stop Switch for the Generator and a switch to operate the Generator
Compartment Blower are located next to AC Distribution Panel in the Galley.
Move the Blower Switch handle to the position where the adjacent indicator light is illuminated.
This indicates that the Blower is operational. The Blower is only operational when the Generator
Battery Disconnect Switch is in the ON position.
J-6