background image

EN-V233 

– 5019 – AA Installation and use of built-in Visio call panel 02-0166-EN  

Page 10 / 12 

diagnosis in the event of a fault 

 

What is the fault? 

What is causing the 

fault? 

How to fix the fault! 

Message on the display: 
« 

Communication

 

error

» 

Incorrect cabling on the 
D+ and/or D- terminals  

- Check cabling between the 3G 
unit, the call panel and the 
central unit: D+ and or D-. 
- The display should show the 
welcome message. 

Keys and display  
not backlit 

- Incorrect cabling on the 
+ and/or - terminals 
- Equipment fault 

- Check cabling on the + and/or - 
terminals 
- Contact our technical support 
department 

Keys 

backlit

 but not 

display (or the reverse) 

 

Contact our technical support department 

The 

LCD

 screen does not 

turn on 

Incorrect cabling on the + 
and/or - terminals 

Check cabling between the 
central unit and the call panel: + / 

When swiping a badge, the 
green LED on the reader 
lights up but the 

door does 

not open

- Relay on the central unit 
not working. 
- Cable to the door 

- Check if relay sticks 
 
- Check cabling between the 
central unit and the door 

If the 

call panel

 says "Call 

in progress" but the 
resident cannot hear the 
visitor 

Incorrect cabling on the 
A+ and/or A- terminals 

Check A+ / A- cabling 

The 

call panel

 says 

"Unable to call" with no dial 
tone 

Telephone network not 
available 

Check cabling to the GSM unit 
and LED levels 

The resident 

cannot see 

the

 

visitor on his/her 

telephone 

- Incorrect V+ / V- cabling 
- Call panel not a Visio 
panel 
- The unit is not a  
3G /3GIP  unit 
- The telephone does not 
support video 

/ “3GIP app” 

not installed 

- Check V+ / V- cabling 
- Install an EEN-PICVIV1 call panel 
instead of an EEN-PIC 
- Install a 3G unit instead of a GSM 
one. 

 

 Contact our technical support department (+33 (0)251 655 529) 

 

Содержание Visio 02-0166-EN

Страница 1: ...ing real time central units 2 to 4 doors ref 03 0101 EN 1 door ref 03 0102 EN Ideal for installation near an entrance gate four opening methods are possible By using an authorised badge By typing in a specific code By calling a resident using the call panel who then opens the gate using a key on his her telephone Using a mobilekey Product description The Visio telephone intercom with scrolling nam...

Страница 2: ...SCENARIO OF CONNECTING AN ENTRANCE GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 E SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT 03 0101 EN 7 C CONFIGURATION WITH AN INTRACODE 03 0102 EN CENTRAL UNIT 8 POST FITTING CHECK 9 A ON THE PANEL 9 B DOOR CONNECTION 9 C CALLS 9 D KEYPAD CODE 9 DIAGNOSIS IN T...

Страница 3: ...EN V233 5019 AA Installation and use of built in Visio call panel 02 0166 EN Page 3 12 Dimensions and assembly A Dimensions of call panel ...

Страница 4: ...EN V233 5019 AA Installation and use of built in Visio call panel 02 0166 EN Page 4 12 B Built in box dimensions ...

Страница 5: ...work if the call panel is installed with a 3G or 3GIP unit B For AUDIO calls only Connect the following terminals up to the central unit Terminal Detail Pair Qty Power supply 1 D D Data 1 A A Audio 1 C For VIDEO calls Also connect the following terminals up to the V V VIDEO 1 terminals on the 3G OR 3GIP unit Terminal Detail Pair Qty V V Video 1 03 0102 EN 17 0101 D D D D V V A A Power supply 12 24...

Страница 6: ...cenario of connecting an entrance gate plus a building It is mandatory to use an 03 0101 EN central unit with in this example an extension board Scenario Audio and Video calls from the entrance gate Only Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension board doors 3 and 4 6 6 2 2 2 In this example door 4 remains available 41 49 and CRT Connections in red refer to Visio...

Страница 7: ...y then the Enter password menu appears o Type the serial number of the 03 0101 EN central unit 000xxxxx o Validate with the V key You are in menu settings mode Menu options in settings mode Setting the clock Date 28 01 13 Day Monday Numeric keys for date entry Key to select day Time 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to selec...

Страница 8: ...ntracode 03 0102 EN central unit Presets selection is performed by switches actuation on the Central unit card on the right hand side of the battery Sw 1 to 3 NA Switch 4 and 5 combination graduate the opening time Sw4 on 5 sec On 10 sec Off 20 sec Sw5 on off on Switch 6 select door open PB type Sw6 on NO off NC ...

Страница 9: ...e central unit guide C Calls To call a resident you have to select his flat s number on the keyboard and then press call pb to validate your selection or cancel pb in any case if you want to reset or make a new selection Trade pb is dedicated to offer a free acces for trades during a time range This function has to be configured on the website in Panel parameters Call button time range Check the q...

Страница 10: ...nals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling between the central unit and the door If the call panel says Call in progress but the resident cannot hear the visitor Incorrect cabling on the A and or A term...

Страница 11: ... telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories m...

Страница 12: ...EN V233 5019 AA Installation and use of built in Visio call panel 02 0166 EN Page 12 12 B Certificate ...

Отзывы: