EN-V233
– 5019 – AA Installation and use of built-in Visio call panel 02-0166-EN
Page 5 / 12
WIRING
See 03-0102-EN guide : V233 - 5002 - XX
See 03-0101-EN guide: V233-5001-XX
A)
General points
POWER SUPPLY : The central unit supplies power to the call panel via the + / - terminals.
CABLING
:
Twisted pairs
– Diameter: 0.8 – Max. distance 100 metres.
Important note:
- The video function will only work if the call panel is installed with a 3G or 3GIP unit.
B)
For AUDIO calls only
Connect the following terminals up to the central unit:
Terminal
Detail
Pair Qty
+ / -
Power supply
1
D-+ / D-
Data
1
A+ / A-
Audio
1
C)
For VIDEO calls
Also connect the following terminals up to the V+ / V- (VIDEO 1) terminals on the
3G OR 3GIP unit:
Terminal
Detail
Pair Qty
V+ / V-
Video
1
03-0102-EN
17-0101
+
-
D+
D-
+ - D+ D-
V+
V-
A+
A-
Power supply: 12 / 24 V
– 2 to 4 A
Not supplied
+ - D+ D-
A+A-
V+
V-
17-0101
03-0101-EN
+
-
D+
D-
A+
A-
Twisted pair
MANDATORY
for video
Twisted pair
recommended
FLUSH-FIT VISIO PANEL
FLUSH-FIT VISIO PANEL