Mechanical installation
4
i
j
| BA 14.0196 | 05/2013
33
X
X
BFK455-008.iso/dms
Fig. 18 Test dimensions and reference dimensions
16. Check of the correct setting (nominal dimension 1.05...1.15 mm):
– For this purpose, position two feeler gauges of the same thickness (e.g. 1.1 mm) for
each tension rod between the hexagon nuts and the complete stator and ensure that
the feeler gauges can be easily moved.
17. Correct the setting if necessary until both feeler gauges can be moved by the same
force.
18. Check the function of the manual release. For this purpose, attach pipe sections onto
the levers and press them together to check whether the motor shaft can rotate freely.
19. Connect Bowden cable (not included in the scope of supply) and pull with approx.
420 N until the motor shaft can be freely rotated.