background image

(257GS)  MODEL 602G FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/25/2014

257

GS

    

SAVE THESE INSTRUCTIONS

English

Page 5

SETUP INSTRUCTIONS

Be sure you have access to water to fill the pool and chemicals for the water. 

IMPORTANT: This filter pump is shipped with the air release valve (1) open (open the air 

release valve if necessary). DO NOT replace the air release valve until you reach STEP #8. 

Failure to follow these instructions will result in air trapped inside filter housing; the motor 

will run dry, be noisy and malfunction.

1. 

Assemble above-ground-pool first. Carefully follow the pool’s installation instructions.

2. 

Place the filter pump the length of the hose away from the pool wall where the lower black 

 

protruding hose connection is "sticking-out".

3.

  Insert the nozzle union 

(9 & 10)

 into the upper protruding hose connections. Then insert the 

strainer union 

(9 & 11)

 into the lower protruding hose connections. The hoses 

(8)

 fit over the 

strainers inserted into the connections.

4.

  There are two hoses to be connected to the filter pump hose connections. With hose clamps 

(7)

fasten one of the hoses 

(8)

 to the lower protruding hose connection (marked "+" on the pool 

liner) and to the upper pump connection (marked "+"). 

5.

  Connect the second hose to the remaining upper protruding hose connection and to the lower 

pump connection. Make sure all the hose clamps 

(7)

 are tight.

6.

  In a counter-clockwise motion unscrew the threaded filter housing collar 

(12)

 from the filter 

housing. Grasp and remove the threaded cover 

(3)

. Check to see if a cartridge is inside the 

 

housing. If yes, replace the cover, finger tighten the housing collar 

(12)

 back onto the filter 

 housing. 

7.

  Fill the pool to a level of at least 1-2 inches above the top connection. The water will 

 

automatically flow down into the pump.

8.

  When water starts flowing out of the air release valve hole, screw in the air release valve back 

into the filter housing cover. Do not over tighten the valve. 

NOTE: Venting the system is 

 

necessary for air to escape as the filter housing fills with water.

9.

  Connect the filter pump to the power outlet. The filter pump is now filtering the water.

10.

 Operate the filter pump until the desired water clarity is obtained.

  NOTE: 

Never put pool chemicals directly into the filter pump. This may damage the pump  

and void the warranty.

WARNING

Risk of electric shock. Connect this product only to a grounding type 

receptacle protected by a ground-fault circuit interrupter (GFCI) or  

residual current device (RCD). Contact a qualified electrician if you  

cannot verify that the receptacle is protected by a GFCI/RCD. Use a  

qualified electrician to install the GFCI/RCD, which has a maximum rate 

of 30mA. Do not use a portable residual current device (PRCD).

Содержание Krystal Clear 602G

Страница 1: ...ex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en...

Страница 2: ...257 GS SAVE THESE INSTRUCTIONS English Page 2 Warnings 3 Parts Reference 4 Setup Instructions 5 7 Maintenance 7 8 Pool Care and Chemicals 8 Long Term Storage 8 Troubleshooting Guide 9 Common Pool Pro...

Страница 3: ...verify that the receptacle is protected by a GFCI RCD Use a qualified electrician to install the GFCI RCD which has a maximum rate of 30mA Do not use a portable residual current device PRCD Always unp...

Страница 4: ...and part numbers NOTE Drawings for illustration purpose only Actual product may vary Not to scale REF NO DESCRIPTION QTY SPARE PART NO 1 AIR RELEASE VALVE 1 10460 2 VALVE O RING 1 10264 3 FILTER HOUSI...

Страница 5: ...protruding hose connection and to the lower pump connection Make sure all the hose clamps 7 are tight 6 In a counter clockwise motion unscrew the threaded filter housing collar 12 from the filter hous...

Страница 6: ...s and insert the hat like plugs into the strainer connectors before servicing the filter After service open the air release valve remove the plugs allow any air to escape through the valve before tigh...

Страница 7: ...ridge be replaced at least every 2 weeks 1 Make sure filter pump is not operating Disconnect line cord 2 To prevent water from escaping the pool unscrew the pool inlet nozzle 10 and strainer grid 11 f...

Страница 8: ...through the liner Filter run time depends on pool size weather and usage level Experiment with various run times so as to produce clean clear water CAUTION Concentrated chlorine solutions may damage t...

Страница 9: ...There s air trapped in the pump housing and inlet hose TROUBLE CAUSE SOLUTION Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RCD R...

Страница 10: ...on pool liner Pool liner is slippery and or has a bad odor Water turns blue brown or black when first treated with chlorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on...

Страница 11: ...e Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE...

Отзывы: