8.  Replacement Parts and Cleaning Supplies 

 

Article description

 

Code

 

Art.-No.

 

AQUALOOP membrane

  

AL-MEM 

230010 

AQUALOOP citric acid concentrate 420 ml 

AL-ACID420 

230091 

AQUALOOP chlorine concentrate 660 ml 

AL-CHLOR660 

230094 

 
 

 

9.  Warranty 

 
For the filter unit, INTEWA GmbH accepts from purchase date, a warranty of 24 months. As proof 
of this date, please keep the purchase receipt. 

Within  the  warranty  period  INTEWA  GmbH,  at  its  discretion,  ensures  factory  defect  repair  or 
replacement. 

The  warranty  does  not  cover  damage  due  to  improper  use,  wear  and  tear,  or  manipulation  by 
third parties. The warranty does not cover those defects which affect the value or usability of the 
device only insignificantly. 

Caution:  

For the quality of the filtered water, the user is responsible. The use of the filtered water for drinking 
water  purposes  may  only  occur  with  a  valid  water  analysis.  Regular  analyses  are  necessary  for 
quality assurance. 
 
 

 

10. Contact 

 

For customers in Germany: 

For questions, ordering spare parts and for service cases, please contact INTEWA GmbH directly 
with the device number and the purchase invoice. 
 

INTEWA GmbH 
Jülicher Straße 336 
52070 Aachen 
 
Tel.: 0049-241-96605-0 
Fax: 0049-241-96605-10 
Email: [email protected] 
Internet: www.intewa.de 
 
 

For customers in other countries: 

For  questions,  ordering  spare  parts  and  for  service  cases,  please  contact  your  dealer  or  the 
responsible  general  importer  who  handles  the  service,  with  the  device  number  and  purchase 
invoice. 

Содержание AQUALOOP tap

Страница 1: ...AQUALOOP TAP Portable drinking water production up to 1600 L day Disinfection of water with power free geodetic pressure www intewa de Assembly and Operating Instructions ...

Страница 2: ...Deliverables 3 4 Technical Data 4 5 Installation 5 6 System Venting and Filtration Operation 7 7 Cleaning and Storage 9 7 1 Mechanical Cleaning 9 7 2 Chemical Cleaning 10 7 3 Storage 10 8 Replacement Parts and Cleaning Supplies 11 9 Warranty 11 10 Contact 11 ...

Страница 3: ... independent from electricity The following raw water sources can be treated by AL TAP Rainwater Surface water River water Well water The following raw water sources cannot be treated by AL TAP Raw water with dissolved organic or inorganic substances which exceed the drinking water regulation limits Domestic and industrial wastewater Application areas Households schools homes Camping grounds Field...

Страница 4: ... the treated water side must also be avoided ie as a result of contamination of the outlet valve This must never lie on the ground but must hang freely If the system is not used regularly the hose system must be cleaned before use The following points must be adhered to for the installation and operation Inspect the product before installation for any visible defects If defects are present the pro...

Страница 5: ...range 0 55 C Max membrane pressure 0 7 bar Max free chlorine 25 C or less 5000 ppm 5 pH during chemical cleaning Max cleaning load free chlorine 1 Mil ppmh cumulative hourly Material HD PE food safe Tank Total weight incl packing 8 kg Membrane cartridge service life up to 10 years 1 Tank 2 Membrane cartridge 3 Ventilation 4 Ventilation valve V1 5 Stop valve V2 6 Suction hose 7 Outlet valve V3 ...

Страница 6: ...s This side is provided with the elbow connection a Top side b Filtration connection under Installation 1 Mount the membrane cartridge with connecting bend in the tank locknut Note The rubber seal must lie on the inside of the container wall 2 Remove the yellow protective plug on the connection and screw into the storage hole in the tank lid The protective plug is required for the mechanical clean...

Страница 7: ...6 3 Assemble the valve unit and ventilation hose 4 Place the AL TAP in an elevated position and assemble hose If necessary shorten suction hose Δ H ...

Страница 8: ... 2 Fill the container with water so that the cartridge is submerged with at least 10 cm of water above 10 cm 3 Wait until the suction hose after stretching out it should hang down is completely filled with water and the water level in the ventilation hose has equalized with the water level in the container approx 10 20 minutes V1 OFFEN V2 OFFEN V3 ZU V1 V2 V3 ...

Страница 9: ...00 L day 0 2 L min 288 L day 1 m 2 0 L min 2880 L day 0 6 L min 864 L day 2 m 3 2 L min 4608 L day 1 0 L min 1440 L day 3 m 4 4 L min 6336 L day 1 4 L min 2016 L day Note The flow rate is strongly dependent on the raw water quality and membrane blockage The suction pressure is only ready if the suction hose is completely vented Table Flow rate as a function of the suction height H and blockage Dur...

Страница 10: ... valve unit and close the connection with the yellow protective plug 2 Loosen the lock nut and remove the membrane cartridge with elbow connection out of the container 3 After close the container with sealing plugs 4 Fill tank to full with water and flush the membrane with plunging movements approx 20 times In reverse order remount the membrane unit and ventilate as described in Chap 6 ...

Страница 11: ...rane cartridge with water equivalent to approx 36 L 2 Start filtration for 6 Liter 3 After 2 hrs filter the water through the membrane to empty 4 If the filtration performance is not achieved see flow rate table repeat above steps 1 3 5 Rinse the system with at least 30 litres of water Cleaning steps for chlorine cleaning 1 Fill the container half full of water and add a single dose of cleaning so...

Страница 12: ...ich affect the value or usability of the device only insignificantly Caution For the quality of the filtered water the user is responsible The use of the filtered water for drinking water purposes may only occur with a valid water analysis Regular analyses are necessary for quality assurance 10 Contact For customers in Germany For questions ordering spare parts and for service cases please contact...

Страница 13: ...12 INTEWA GmbH Version 1 0 b Subject to technical changes ...

Отзывы: