64
Error
Cause
Remedy
Too frequent chemical
cleaning, flow remains low
-
Chlorine tank is empty.
-
Backwash pump is defective.
-
Membrane is irreversibly
blocked.
-
CIP valve is defective.
-
Check the amount of available
Chlorine.
-
Check the functionality of the
backwash pump in test mode.
-
Check the runtime of the
membrane (max. 10 years).
Replace it by a new one or clean it
by hand.
-
Check the function of valve V0.
Informative: Maximum level
of the bioreactor
Note: Flashing external warning lamp
and audible signal ON/OFF (1 sec. / 1sec.)
-
Level sensor detected the
maximum level in the
bioreactor
-
Only informative, alarm has to be
confirmed manually (NSF
requirement)
Process sticks in filtration,
break or backwash.
-
Wrong settings in process flow.
-
Check the settings in process flow.
Check the units of the different
times.
No process is running/
Current process: none
-
Check the process flow
-
Switch the process control to off
and on again. If you want to use
automatic process control, check
the operation hours in the
belonged settings.
Alarm on pumps
-
Pumps are blocked at suction
side or on the pressure side.
-
Not enough water available.
-
Valves are closed because of
incorrect settings.
-
Check the position of the pumps
und check both sides.
-
Check if enough water is available.
-
Check the alignments of the
valves.
Prefilter blocked
-
Too much fouling on the
lattice.
-
Valve of the prefilter is defect.
-
Clean the lattice by hand.
-
Check the function of the prefilter
valve.
Clear water tank remains
empty though filtration
-
Continuous use of clear water.
-
Ball valve has wrong settings.
-
If necessary, set longer filtration
times.
-
Check the alignment of ball valve.
Filling level is detected
incorrectly
-
Wrong settings at height
overflow
-
Make sure you have entered the
correct overflow heights
Not expansion modules
available
-
The incorrect amount of
expansion modules are set
-
Water gets dirty
-
Sludge pump is defect
-
Check the sludge pump in test
mode and by hand.
Note:
If there are any questions or further support is necessary please contact your local service provider. The local
service address is stated on the control unit (see section. 8.1).
Содержание AQUALOOP GW 10800
Страница 10: ...9 Tab Official listing https www intewa de en applications rain greywater harvesting greywaterrecycling...
Страница 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Страница 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Страница 37: ...36 Fig Electrical connection plan upper pump lower pump...
Страница 39: ...38 Fig Control cabinet of multiple membrane station controller...
Страница 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Страница 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Страница 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...