Test
Sub Menu
Parameters
Throughput
• Test Time (s): Set the Throughput test time, range from 1 to 999, the default value is 60s
• Test Count: Select the times for Throughput test, range from 1 to 60, the default value is 1
• Initial Rate: Set the initial rate for Throughput test, range from 0.01% to 100%, the
default value is 100%
• Minimum Rate: Show the minimum time run which the programme required to run
under the best condition, range from 0.01% to 100%, the default value is 10%
(Note: The minimum time will be calculated and upgraded when the test has been started.)
• Maximum Rate: Set the maximum rate for Throughput test, range from 0.01% to 100%,
the default value is 100%
• Accuracy: Set the accuracy value, range from 0.01% to 100%, the default value is 0.5%
(Note: The accuracy will be calculated based on the Ethernet link rate.)
• Acceptable Loss Rate: Set an acceptable package loss rate, range from 0.00 to 100, the
default value is 0.00
Figure 7.21 Throughput Setting
Back-to-Back
• Test Time (s): Set the Back-to-Back test time, range from 1 to 999, the default value is 2s
• Test Count: Select the times for Back-to-Back test, range from 1 to 60, the default value is 5
• Initial Test Time Ratio: Set the initial rate for Back-to-Back test, range from 0.01% to
100%, the default value is 100%
• Minimum Test Time Ratio: Show the minimum time run which the programme required
to run under the best condition, range from 0.01% to 100%, the default value is 50%
(Note: The minimum time will be calculated and upgraded when the test has been started.)
• Maximum Test Time Ratio: Set the maximum rate for Back-to-Back test, range from
0.01% to 100%, the default value is 100%
• Accuracy: Set the accuracy value, range from 0.01% to 100%, the default value is 0.50%