17
WIRING INFORMATION
All internal electrical wiring is completed at the factory. All external wiring must
conform to the National Electric Code and any local codes. Line voltage leads utilize
wire nut connections.
A surge suppressor should be installed to protect control board.
Surge suppressors are available now that mount to your breaker box
providing protection to your whole house.
Refer to the wiring diagrams for all field wiring.
A.
Field connections should be protected with a 15-amp fuse.
B.
Install the room thermostat on an inside wall away from cold drafts,
windows, or heat from fireplaces, appliances, or sunlight. Set the heat
anticipator at .1 amps. Connect the thermostat leads to the yellow wires on
control board.
C.
Install a separate fused disconnect switch near the unit so power can be
shut off for servicing.
D.
Shut off service switch when the boiler is not in use for extended periods.
E.
Failure to provide surge protection will void control board warranty.
WARRANTY
The limited warranty is not applicable unless these installation instructions are
followed.
HOMEOWNER INFORMATION
A.
COMBUSTION AIR SUPPLY
Your burner requires an ample amount of clean combustion air in order, to
completely and efficiently burn its fuel. If an ample supply is not available
erratic operation, noise combustion, and fuel odours in the air may result.
REMEMBER THAT VENTING FANS OR A VENTER DRYER WILL GREATLY
INCREASE THE NEED FOR OUTSIDE AIR.
B.
AREA AROUND THE BOILER
The area around the boiler should be kept clean and free or any combustible
materials, particularly oily rags or papers. The boiler should be accessible for
ease of service.
SERVICE INFORMATION
To avoid unnecessary expense and inconvenience, the boiler and burner, should be
inspected at least once a year by a qualified serviceman. If difficulty occurs, the
following should be observed before calling the serviceman:
A.
Check to see if the thermostat setting is above room temperature
B.
Check to see if the service switch is in the on position
DO NOT TAMPER WITH THE UNITS OR CONTROLS
POWER FAILURE
In case of power failure the combustion fan will stop and the fuel feeding motors will
stop feeding fuel to the fire pot. If this happens switch the primary control on/off
switch to DRAFT FAN. Should the power come back while the fire is smouldering the
emissions will be evacuated from the boiler, also this will prevent fuel from being fed
into the fire pot. When power is resumed and the fire is extinguished the boiler can be
safely restarted following the START-UP INSTRUCTIONS.