The batteries have no electricity 

Replace the batteries 

LED displays error code 

“E1”

 

Tube temperature sensor failure   

Check the tube temperature sensor and 

related circuits 

LED displays error code 

“E2”

 

Room temperature sensor failure 

Check the room temperature sensor and 

related circuits 

LED displays error code 

“E4”

 

Anti-freeze protection 

Restore the functions automatically 

once anti-freeze protection is over. 

Water-full indicator lights  The water in chassis is full   

Drain the water and re-start the unit 

       

 

 

 

 

 

 

 

 

Appendix 

Fuse parameters 

Model: FSD or 50F 

Voltage: 250V 

Current: 3.15A 

Schematic diagram of the air conditioner 

 

For specific technical parameters of the model, refer to rating label on the product. 

   

 

 

Correct Disposal of this product 

This marking indicates that the product should not be disposed with other household wastes throughout the 

EU.  To  prevent  possible  harm  to  the  environment  or  human  health  from  uncontrolled  waste  disposal,  recycle  it 

responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and 

collection systems or contact the retailer where the product was purchased. They can take this product for environmental 

safe recycling.   

Condenser 

Compressor 

Evaporator 

Capillary 

Содержание DELLA

Страница 1: ...ual Part Number 048 GM 48266 Thank you very much for selecting this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Plea...

Страница 2: ...hnical Specification 5 Features and Identification of Parts 6 Operation and Settings 8 Protection 12 Handling and Transportation 12 Installation and Adjustment 13 Drainage Instruction 16 Maintenance a...

Страница 3: ...electrical shock or injury when using your air conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do...

Страница 4: ...ns see Installation and Adjustment Keep the drain hose in good condition without flexure then connect with unit Manually adjust the vertical and horizontal louvers slightly to protect louvers from any...

Страница 5: ...accessible by panel control and remote control Temperature setting range of this unit is 17 30 62 86 This unit is designed with various protection functions such as 24 hour programmable timer auto co...

Страница 6: ...d winding pillar and universal plug fixing holes can well protect the power cord High position of exhaust air outlet easy assembly and exhaust venting quickly 24 hour Timer function unique on off remi...

Страница 7: ...aust hose adapter 25 Window seal plate assembly Operation and Settings 1 Control Panel This section explains proper mobile air conditioner operation Figure 3 On Off button Mode button Up button Timer...

Страница 8: ...o convert Celsius degrees and Fahrenheit degrees and corresponding indicator will light up 4 Adjust fan speed Press the button to select a desired fan speed shown below 5 Stand by Press the button aga...

Страница 9: ...room temperature is shown on LED display window z Press Timer button to set automatic ON time while unit is off will light up z The unit will turn on automatically and working at original mode when th...

Страница 10: ...ect Cool mode Button press this button to select Fan mode Button press this button to select Dry or dehumidifying mode Button press this button to select Sleep function under cooling mode Before using...

Страница 11: ...e anti frost protection and all buttons on control panel except for power button are inactive Once the tube temperature 8 the protection is relieved to recover into original status and compressor appl...

Страница 12: ...bly and its adapter 1 Take out the exhaust hose assembly and its adapter from plastic bag 2 Extend the exhaust hose at one end screw the round end of adapter into exhaust hose at anticlockwise directi...

Страница 13: ...emarks z Keep the right direction of slant side A of adapter for ease installation of window seal plate z Keep exhaust hose assembly be strongly locked by fasteners in exhaust outlet to avoid its fall...

Страница 14: ...se adapter and set them together then slide adapter downwards to make 2 set of openings locked for 2 parts good connection B Lock self tapping screw 4mm into adapter hole Remarks z Slide the adapter d...

Страница 15: ...efore the tray is full if it can t hold all water in the unit to prevent the water leakage and wet the floor or carpet l Water stopper and drain cover must be tightly installed to avoid new condensate...

Страница 16: ...e to take out the filter to avoid any twist or damage to filter z Take out filters of back panel at first then side panel 2 Clean the filters gently in warm water about 40 mixed with detergent and dry...

Страница 17: ...before asking for professional service but never dismantle or repair the unit by yourself it may cause harm to you and your property Trouble Cause Remedy The unit fails to start up Power supply failu...

Страница 18: ...arameters Model FSD or 50F Voltage 250V Current 3 15A Schematic diagram of the air conditioner For specific technical parameters of the model refer to rating label on the product Correct Disposal of t...

Отзывы: