background image

www.intertec.info

Operating Instructions SL BLOCKTHERM DB.A

HOM146759307Ien-5

Page 3 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

General

These  operating  instructions  describe  the  safe  and
proper way to work with the device. The safety informa-
tion  and  instructions  given  as  well  as  the  local  accident
prevention  regulations  and  general  safety  regulations
valid  in  the  area  of  application  must  be  complied  with.
These  instructions  are  a  constituent  part  of  the  instru-
ment and need to be kept in the immediate vicinity of the
device accessible to personnel at all times.

Before  starting  any  work,  the  operating  instructions
should be read in full.

2

Use

The SL..THERM heaters are manufactured according to
Directive INMETRO No. 179, of May 18

th

, 2010 and are

licensed for direct heating through flange-mounting (con-
duction)  or  for  room  heating  (convection)  in  Ex-zone  1
and  Zone  2  for  instrument  categories  G/  D  in  temperat-
ure classes T3 to T6. You will find the temperature class
for  your  device  on  the  label.  See 

Technical  Data  [

}

Page 4]

 section.

The areas of application are:

• Frost protection

• Condensation protection

• Maintaining temperature

As  an  option,  thermostats  can  be  integrated  in  the  con-
necting cable. If a TAE is used, the respective operating
instructions must be complied with.

Product  approval  NCC  17.0104  X  with  appendices  and
supplements,  as  well  as  IEC  Scheme  Certificate  IECEX
PTB 07.0055X.

See http://www.intertec.info

3

Special conditions for safe use

1. The heater may only be installed and operated in en-

closures whose absolute heat transfer coefficient is
not less (not better) than 0,5 W/K.

2. The connecting cable must have a fixed installation

and must be protected mechanically.

3. If connection is made in the potentially explosive

area, the connecting lead shall be connected by
means of an enclosure that meets the requirements
of a type of protection specified in ABNT NBR IEC
60079-0.

4. Installation shall be made with due regard to the

maximum permissible temperatures of neighbouring
components, the minimum clearances and, where
required, the mounting position.

5. Additional conditions for alternate use of thermostats

see concerning test certificate. They have to be sep-
arately certified to the same standards.

6. Special conditions for some connecting cables have

to be included in the operating manual and have to
be noticed by the installer.

7. lf used in dust-ex-areas the concerning requirements

of ABNT NBR IEC 60079-14, of ABNT NBR IEC
60079-17 and ABNT NBR IEC 60079-19 have to be
considered.

4

Explanation of symbols for warnings
and signal words

The  safety  information  warns  the  user  about  risks  and
provide information on how risks can be avoided.

Safety  information  can  be  found  at  the  start  of  the
chapter before the instructions which may lead to a haz-
ardous  situation.  Additional  safety  information  can  be
found at the beginning of this manual.

Safety  instructions  which  must  be  adhered  to  are  high-
lighted as follows:

 DANGER

DANGER

This sign is warning about an extremely hazardous situ-
ation which, if not heeded, will lead to death or serious ir-
reversible injury.

 WARNING

WARNING

This sign is warning about a hazardous situation which,
if not heeded, may lead to death or serious irreversible
injury.

 CAUTION

NOTICE

This sign is warning about a hazardous situation which,
if not heeded, may lead to slight, reversible injury.

Содержание SL BLOCKTHERM DB.A

Страница 1: ...Operating Instructions SL BLOCKTHERM DB A HOM146759307Ien 5 05 02 2020...

Страница 2: ...e 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Technical Data 4 7 Option BLOCKTHERM ADA with aluminium plate 4 8 Installation...

Страница 3: ...sfer coefficient is not less not better than 0 5 W K 2 The connecting cable must have a fixed installation and must be protected mechanically 3 If connection is made in the potentially explosive area...

Страница 4: ...60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant...

Страница 5: ...NOT exceed the trigger temperature of the limiter The operating temperatures must be adhered to The connection cable must be permanently installed up to the inlet into the on site junction box taking...

Страница 6: ...ent devices with a measured triggering residual current of 30 mA are preferable In an IT system an insulation monit oring device needs to be used which switches off the supply as soon as the insulatio...

Страница 7: ...the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requireme...

Страница 8: ...9 Vers o Corrigida 2 2011 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0104 X Ex tb IIIC T85 C T100 C T135 C T200 C Db Ex db...

Отзывы: