background image

www.intertec.info

Operating Instructions SL BLOCKTHERM DB.A

Page 4 / 8

HOM146759307Ien-5

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

5

Safety information

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 265 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in compli-

ance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm²

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 5

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof alu-

minium, black anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Profile type "K" Length x

Width x Height

90 x 40 x 30

mm

Profile type "L" Length x

Width x Height

105 x 40 x 30

mm

Profile type "P" Length x

Width x Height

225 x 50 x 45

mm

 INFO

You will find the precise technical data for your in-
strument on the label. You will find information on
the heating output on the data sheet.

Rated output

Rated voltage/Operating voltage

Thermostat

Temperature class

Illustration 1: 

Example: SL BLOCKTHERM DBPA 150 T3 TS10

label

7

Option BLOCKTHERM ADA with
aluminium plate

Illustration 2: 

SL BLOCKTHERM DLA T4 ADA

The  BLOCKTHERM  heater  is  fixed  to  a  black  anodized
aluminium plate for a better heat transfer. The plate may
be mounted anywhere on the device to be heated.

In  combination  with  the  plate  only  the  profile  type  “L”  is
available. See 

Technical Data [

}

Page 4]

Содержание SL BLOCKTHERM DB.A

Страница 1: ...Operating Instructions SL BLOCKTHERM DB A HOM146759307Ien 5 05 02 2020...

Страница 2: ...e 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Technical Data 4 7 Option BLOCKTHERM ADA with aluminium plate 4 8 Installation...

Страница 3: ...sfer coefficient is not less not better than 0 5 W K 2 The connecting cable must have a fixed installation and must be protected mechanically 3 If connection is made in the potentially explosive area...

Страница 4: ...60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant...

Страница 5: ...NOT exceed the trigger temperature of the limiter The operating temperatures must be adhered to The connection cable must be permanently installed up to the inlet into the on site junction box taking...

Страница 6: ...ent devices with a measured triggering residual current of 30 mA are preferable In an IT system an insulation monit oring device needs to be used which switches off the supply as soon as the insulatio...

Страница 7: ...the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requireme...

Страница 8: ...9 Vers o Corrigida 2 2011 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0104 X Ex tb IIIC T85 C T100 C T135 C T200 C Db Ex db...

Отзывы: