![INTERSPIRO Spiroguide II Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/interspiro/spiroguide-ii/spiroguide-ii_user-manual_2080593018.webp)
18
OPTIONAL WARNINGS
ADSU/PASS PRE-ALARM (SEE SECTION 9)
RED IS FLASHING
ADSU/PASS ALARM (SEE SECTION 9)
RED IS LIT
INTERNAL EVACUATION SIGNAL (SEE SECTION 9)
RED IS LIT
LINKING THE HUD
The HUD must be linked together with the SCBA (BAC) before use. The linking only
needs to be performed once as long as the same SCBA (BAC) and HUD will be used
together. If a SCBA will be used with different HUDs it has to be linked before each use.
The linking of the HUD can only be performed with the SCBA unpressurized.
1.
Press and hold the black button on the Digital Display Unit until the display reads
“CONNECTING”.
2.
Place the magnet located on the Tally Key (Fig. 7-A) to the side of the HUD having
two LEDs, the right hand side when wearing the mask. The red and yellow LED lights
up.
3.
When removing the Tally key the red light goes out and the yellow continues. The
4.
Within approximately 20 seconds the HUD and BAC will link. The BAC beeps, the
Digital display reads “HUD CONNECTED” and all six LEDs in the HUD flash two times.
WARNING!
IF NOT ALL LEDS ON THE HUD ARE LIT IT MUST BE IMMEDIATELY BE REMOVED FROM SERVICE.
5.
Press and hold the black button on the Digital display until it switches off.
CHECK HUD LINK
The HUD link can be checked to ensure that the HUD is linked to the correct SpiroGuide
II.
To check the HUD link, hold the backlight button for two seconds, release it for one
second and then hold it again for two seconds. After the Backlight button has been
released, the two LED lights on the righ hand side of the HUD will start to flash if it is
linked to the SpiroGuide II unit.
NOTE:
ONLY ONE USER CAN CHECK THE HUD LINK AT THE TIME. IF SEVERAL USERS TEST THE HUD LINK AT ONCE IT WILL
BE IMPOSSILBLE TO TELL IF THE HUD IS LINKED TO THE CORRECT SPIROGUIDE II OR NOT.
BREATHING APPARATUS COMPUTER (BAC)
The BAC is measuring the pressure and supplying the information to the Digital Display
and HUD. It logs all usage data which can be accessed with a PC interface (optional).
During Run mode, the main LED flashes yellow as a position light.
In addition to the main LED, there are two yellow LEDs for added visibility.