10
4 ADJUSTING SIZE
NOTE!
WHEN STANDING STRAIGHT WITH THE BREATHING APPARATUS DONNED THE MAJORITY OF THE WEIGHT SHALL BE
CARRIED ON THE HIPS AND NOT THE SHOULDERS.
To adjust the height of the hip belt, push the red buttons under the hip belt together and
slide the complete hip belt up or down to the correct size. [Fig. 12]
The harness can be adjusted into four different sizes. Size indications are available on
both the front and backside of the harness.
5 DONNING
NOTE!
THIS SECTION DESCRIBES HOW TO DON THE APPARATUS PERFORMING A “SHORT TEST” DURING THE START-UP.
FURTHER INFORMATION REGARDING THE START-UP TEST AND INSTRUCTIONS FOR PERFORMING THE “FULL TEST” ARE GIVEN
IN SECTION 6.
1.
Connect the breathing hose to the breathing valve. [Fig. 13]
2.
Connect the face mask and breathing valve according to the instructions given in the
user manual for the face mask.
3.
Loosen the shoulder straps and the waist belt and put on the apparatus.
4.
Place the neck strap over the head.
5
.
Fasten the waist belt buckle and tighten, ensuring that the majority of the weight is
carried on the waist and not the shoulders. [Fig. 14]
6
.
Adjust the shoulder straps and tuck in any loose straps. If applicable fasten the
chest strap and tighten, tuck in any loose straps. [Fig. 15]
7.
Switch off positive pressure.
8.
Open the cylinder valve fully. The apparatus now starts to perform the start-up test.
9.
Check that the HUD is fully pushed down inside the mask.
10.
Don the face mask according to the instructions given in the face mask user manual.
11.
Check the Digital Display and confirm “TEST OK” or failure indication (see section 6)
by pressing the backlight button (section 7, Fig. 7-A) on the display.
6 START-UP TEST
“SHORT TEST” AND “FULL TEST”
When the cylinder valve is opened, an automatic start-up check is performed.
Depending on user interaction, either a “Short Test” or a “Full Test” is performed.
The Short Test is performed in accordance with the section “Performing the Short Test”
and automatically performs the following tests:
- Cylinder pressure above pre-set level (configuration dependent)
- Battery has at least two hours of operation
- Electronic systems are working