Troubleshooting
Fault
Cause
Remedy
Conveying goods jam
between the side guides
Conveying goods sit on the
module at an angle
Align conveying goods parallel
to the side guide
Center of gravity of the load is
not centered
Align the center of gravity of the
load
Transport process cannot
be started and motor does
not run
Main switch and/or control
turned off
Check the switch position; turn
on main switch and/or key
switch of the control as required
Supply line damaged
Check supply line
Transport process cannot
be started and motor is
running
Control or ball module conveyor
too loose
Retension control or ball module
conveyor
Transport weight too high
Observe maximum weight
Transport shows jerky
movements
Foreign objects in roller area
Remove foreign objects
Conveying goods are not
being transported
Drum motor (control belt)
defective
Replace belt conveyor with
defective motor,
see "Replacing
Drum motor (ball module
conveyor defective
Replace defective motor,
"Replacing the drum motor",
page 57
Defective roller
Replace defective roller