Chapter 8: Troubleshooting
5536 PRI RAS Communications Controller Users Guide
125
Digital Modem
RAS Dial-out
failed
The following possible solutions assume a successful
LoopTest. (If you do not know how to access the
Remote Access Setup dialog box or otherwise check
the following items, see
.)
1.
Make sure the remote called number is equipped
with a modem.
2.
Make sure the correct speech coding law for digital
modem channels is selected in Digital Modems
Properties dialog box. (See
.)
3.
Make sure at least one digital modem RAS port is
configured to make outgoing calls. (On the Remote
Access Setup dialog box, select a port and click
Configure
.)
4.
Make sure the protocol(s) used by the remote user
(IP, IPX/SPX, or NetBEUI) are configured in RAS
dial-out protocols. (On the Remote Access Setup
dialog box, click
Network
.)
5.
Check your user ID and password.
6.
Use SynWatch to see if an ISDN connection
problem exists. See
7.
Use SynWatch to see if a PPP negotiation problem
exists.
Problem
Possible Solution(s)
Содержание ENTIA 5536 DM PRI
Страница 34: ...Minimum System Requirements 14 Interphase Corporation...
Страница 46: ...Connecting to an MVIP Bus 26 Interphase Corporation...
Страница 56: ...Connecting to the Network 36 Interphase Corporation...
Страница 90: ...Removing the Drivers 70 Interphase Corporation...
Страница 136: ...Verifying COM Ports 116 Interphase Corporation...
Страница 172: ...Saving and Editing Frames 152 Interphase Corporation...
Страница 182: ...Understanding LoopTest Messages 162 Interphase Corporation...
Страница 190: ...Setting Port and Clock Modes 170 Interphase Corporation...
Страница 196: ...Interpreting Line Status Indicators 176 Interphase Corporation...
Страница 208: ...Procedures 188 Interphase Corporation...
Страница 220: ...Europe 200 Interphase Corporation...
Страница 238: ...Glossary 218 Interphase Corporation...