background image

 

Page 7

 
 
 
 
 
 
 
 
 
 
 

 

4.  Use  a  3/16”  drill  bit  to  drill  3  starter  holes  ½” 

deep through the 3 holes in the cabinet and into 
the window sill. 

5.  Attach  cabinet  to  windowsill  with  3  -  #10  x  ½” 

pan-head Phillips screws. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

6.  Check that the air  conditioner cabinet is  tilted ½ 

bubble on carpenters level to the outside so that 
water will run to the outside. 

 

On some models 

 

Select  the  position  that  will  place  the  sill  supports 
near  the  outermost  point  on  the  sill.  Place  the  short 
side  of the sill  supports, on the case bottom, toward 
the window. Attach the sill supports to the case track 
hole  in  relation  to the  selected  position  using  2  type 
B screws in each support. 

 

CAUTION:

 Do not install this air conditioner in 

a window if the bolts do not contact the window sill. 

 
 
 
 
 
 

Attach Side Curtains to Window Frame 
1.  Pull  left-hand  curtain  out  until  it  fits  into  window 

channel. Use a 3/32” drill bit to drill a starter hole 
through  the  hole  in  the  curtain  housing  and  into 
the lower window sash. 

 
Front View 

 
 
 
 
 
 
 
 
 
 
Top View  
 
 
 
 
 
 
 
 
 
 
 
 

2.  Insert  one  of  the  #10  x  ¾”  round-head  screws 

through hole and into  lower window sash. Insert 
one of the  #10 x ¾” round-head screws through 
threaded hole in top of curtain and one in bottom 
of curtain. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.  Repeat for right-hand curtain. 

 

Complete Window Installation 
 
1.  Insert  foam  seal  behind  the  top  of  the  lower 

window sash and against the glass of the upper 
window. 

2.  Place  window-lock  bracket  on  top  of  lower 

window and against upper window sash. 

Содержание WHP412230R

Страница 1: ...INDOW HEAT PUMP USER MANUAL 950 0190revD 02 19 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9 200 9 500 BTU 11 200 11 600 BTU WHP412230R WHP412ZR 8 100 8 400 BTU 10 000 10 300BT...

Страница 2: ...le air conditioner is an environmentally safe and friendly ATTENTION Keep small children away from portable unit Do not modify or otherwise defeat the plug The appliance shall be installed and operate...

Страница 3: ...nife Parts Supplied A Foam window sash seal B Window lock brackets 2 C 10 x 1 4 pan head Phillips screws 6 D 10 x 3 8 pan head Phillips screws 3 or 7 E 10 x 3 4 round head screws 6 F 10 x 1 2 pan head...

Страница 4: ...ou will need to modify them for other types of windows The air conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting...

Страница 5: ...e may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current I...

Страница 6: ...ditioner on cardboard 5 Remove any packing foam from inside of unit NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Window...

Страница 7: ...ing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into...

Страница 8: ...pe B screws in each support CAUTION Do not install this air conditioner in a window if the bolts do not contact the window sill Attach Side Curtains to Window Frame 1 Pull left hand curtain out until...

Страница 9: ...rd exits the air conditioner should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner...

Страница 10: ...on both sides of cabinet 3 Insert front tabs of front panel into top of cabinet and swing front into place 4 Attach bottom front of panel with front panel screws NOTE For wall installations if needed...

Страница 11: ...r heating Use the Temperature Increase Decrease pads to set the desired temperature between 64 F and 86 F in 1 F increments The display will indicate the set temperature in the heat mode Your window u...

Страница 12: ...air conditioner off wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Press buttons Increase and Decrease at the sam...

Страница 13: ...ll be activated and the compressor will turn off 7 Delay Button Used to select the amount of time before the air conditioner turns off when on or the amount of time before the air conditioner turns on...

Страница 14: ...the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal conditions the unit can evaporate th...

Страница 15: ...detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the Front Panel 1 Turn off the air cond...

Страница 16: ...st 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Rese...

Страница 17: ...conditioner to cool off a very hot room Windows or doors to the outside are open Close all windows and doors The temperature set point or Thermostat control is not at a cool enough setting Adjust the...

Страница 18: ...0P Power Cord Rating amps 18A 18A Power Cord Length Inches 59 59 Minimum Circuit Breaker Size amps 20A 20A Minimum Circuit Capacity amps 20A 20A Refrigerant Charge R410a oz 24 69 28 22 Max dbA Level I...

Страница 19: ...provides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excl...

Отзывы: