background image

 

Page 2

INSTALLATION REQUIREMENTS 

Tools and Parts 

Gather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed here. 

 
 

Tools Needed 

 

Flat-blade and Phillips head screwdriver 

 

Drill and 3/16” or smaller bit 

 

Pencil 

 

Ruler or tape measure 

 

Level 

 

Scissors or Utility knife 

 

 

Parts Supplied 

A.  Foam window sash seal 
B.  Window lock brackets (2) 
C.  #10 x 1/4” pan-head Phillips screws (6) 
D.  #10 x 3/8” pan-head Phillips screws (3 or 7) 
E.  #10 x 3/4” round-head screws (6) 
F. 

#10 x 1/2” pan-head Phillips screws (3) 

G.  Top channel 
H.  Side curtains (2) 
I. 

Foam seal 

J. 

Sill support (2) Nut (2) Bolt (2) 

K.  Condensate Drain Cup (1) 

NOTE: 

 

Mounting Parts provided varies per unit of different capacity. Please check your accessories bag carefully 
when you open the carton. 

 

Installation parts are supplied for double-hung windows up to 39” wide.  

 

 

Содержание WHP412230R

Страница 1: ...INDOW HEAT PUMP USER MANUAL 950 0190revD 02 19 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9 200 9 500 BTU 11 200 11 600 BTU WHP412230R WHP412ZR 8 100 8 400 BTU 10 000 10 300BT...

Страница 2: ...le air conditioner is an environmentally safe and friendly ATTENTION Keep small children away from portable unit Do not modify or otherwise defeat the plug The appliance shall be installed and operate...

Страница 3: ...nife Parts Supplied A Foam window sash seal B Window lock brackets 2 C 10 x 1 4 pan head Phillips screws 6 D 10 x 3 8 pan head Phillips screws 3 or 7 E 10 x 3 4 round head screws 6 F 10 x 1 2 pan head...

Страница 4: ...ou will need to modify them for other types of windows The air conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting...

Страница 5: ...e may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current I...

Страница 6: ...ditioner on cardboard 5 Remove any packing foam from inside of unit NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Window...

Страница 7: ...ing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into...

Страница 8: ...pe B screws in each support CAUTION Do not install this air conditioner in a window if the bolts do not contact the window sill Attach Side Curtains to Window Frame 1 Pull left hand curtain out until...

Страница 9: ...rd exits the air conditioner should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner...

Страница 10: ...on both sides of cabinet 3 Insert front tabs of front panel into top of cabinet and swing front into place 4 Attach bottom front of panel with front panel screws NOTE For wall installations if needed...

Страница 11: ...r heating Use the Temperature Increase Decrease pads to set the desired temperature between 64 F and 86 F in 1 F increments The display will indicate the set temperature in the heat mode Your window u...

Страница 12: ...air conditioner off wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Press buttons Increase and Decrease at the sam...

Страница 13: ...ll be activated and the compressor will turn off 7 Delay Button Used to select the amount of time before the air conditioner turns off when on or the amount of time before the air conditioner turns on...

Страница 14: ...the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal conditions the unit can evaporate th...

Страница 15: ...detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the Front Panel 1 Turn off the air cond...

Страница 16: ...st 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Rese...

Страница 17: ...conditioner to cool off a very hot room Windows or doors to the outside are open Close all windows and doors The temperature set point or Thermostat control is not at a cool enough setting Adjust the...

Страница 18: ...0P Power Cord Rating amps 18A 18A Power Cord Length Inches 59 59 Minimum Circuit Breaker Size amps 20A 20A Minimum Circuit Capacity amps 20A 20A Refrigerant Charge R410a oz 24 69 28 22 Max dbA Level I...

Страница 19: ...provides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excl...